WWW.BIGASSSOLUTIONS.COM © 2016 DELTA T CORP. ALL RIGHTS RESERVED.
1
TECHNICAL SPECIFICATIONS
Powerfoil X3.0
Fan
Diameter
Motor Size
Minimum Circuit Size Full Load Amps (Fan)
PFX3-08
8 ft
(2.4 m)
1.0 hp
(0.75 kW)
20 A @ 200–240 V, 1 Φ
10 A @ 200–240 V, 3 Φ
10 A @ 400–480 V, 3 Φ
4.4 A
3.2 A
1.5 A
PFX3-10
10 ft
(3.0 m)
30 A @ 200–240 V, 1 Φ
20 A @ 200–240 V, 3 Φ
10 A @ 400–480 V, 3 Φ
8.7 A
5.0 A
2.5 A
PFX3-12
12 ft
(3.6 m)
1.5 hp
(1.1 kW)
30 A @ 200–240 V, 1 Φ
20 A @ 200–240 V, 3 Φ
10 A @ 400–480 V, 3 Φ
10 A @ 575–600 V, 3 Φ
8.7 A
5.0 A
2.5 A
1.9 A
PFX3-14
14 ft
(4.3 m)
PFX3-16
16 ft
(4.9 m)
PFX3-18
18 ft
(5.5 m)
2.0 hp
(1.5 kW)
30 A @ 200–240 V, 1 Φ
20 A @ 200–240 V, 3 Φ
10 A @ 400–480 V, 3 Φ
10 A @ 575–600 V, 3 Φ
10.7 A
6.2 A
3.0 A
2.5 A
PFX3-20
20 ft
(6.1 m)
PFX3-24
24 ft
(7.3 m)
Note: All variable frequency drives produce 3-phase output power regardless of input phase.
Powerfoil X3.0 Plus
Fan
Diameter
(with Plus Winglets)
Motor Size
Minimum Circuit Size Full Load Amps (Fan)
PPX3-10
12 ft
(3.6 m)
1.5 hp
(1.1 kW)
30 A @ 200–240 V, 1 Φ
20 A @ 200–240 V, 3 Φ
10 A @ 400–480 V, 3 Φ
10 A @ 575–600 V, 3 Φ
8.7 A
5.0 A
2.5 A
1.9 A
PPX3-12
14 ft
(4.3 m)
PPX3-14
16 ft
(4.9 m)
PPX3-16
18 ft
(5.5 m)
2.0 hp
(1.5 kW)
30 A @ 200–240 V, 1 Φ
20 A @ 200–240 V, 3 Φ
10 A @ 400–480 V, 3 Φ
10 A @ 575–600 V, 3 Φ
10.7 A
6.2 A
3.0 A
2.5 A
PPX3-18
20 ft
(6.1 m)
PPX3-20
22 ft
(6.7 m)
PPX3-24
24 ft
(7.3 m)
Note: All variable frequency drives produce 3-phase output power regardless of input phase.