27
10. DISPOSAL
At the end of its useful life, you have to scrap and dispose of this product by taking it to a local differentiated waste collection center in conformity
to law.
Before scrapping, check the serial number plate on the machine: if it has the symbol , it means that disposal is regulated by EU Directive 2003/96
(Waste Electrical and Electronic Equipment, WAEE).
The user must inquire about the local electrical and electronic waste collection system and follow its instructions.
Illegal disposal of this product with normal domestic waste can seriously harm the environment and health and is subject to administrative penalties.
GB
OPERATIONAL PROBLEMS
CAUSES
SOLUTIONS
• Loss of oil between head and pump body
• Pump body side seal rings worn
• Replace the seal rings
• Loss in the spray gun
• Replace the spray gun
• Losses from the high pressure pipe or
•
from other parts of the hydraulic circuit
• Check the status of the H.P. pipe and the
•
entire hydraulic circuit
• Defective adjustment valve
• Disassemble the valve and clean or replace it
• Detergent filter clogged
• Clean filter or replace it
• Detergent tap closed
• Open the tap or replace it
• Empty recipient
• Fill the recipient
• Check diesel oil level and, if necessary, fill the tank
• Clean and/or replace the diesel oil pump
• Clean and/or replace the diesel oil filter
• Damaged diesel oil pump/motor coupling joint
• Replace the joint
• Dirty or ruined diesel oil nozzle
• Clean the nozzle with the compressed air or with
•
the diesel oil and replace it
• Air in the diesel oil aspiration pipes
• Check all joints are tightly connected
• Diesel oil solenoid valve not functioning
• Clean and/or replace the solenoid valve
• Check the ignition transformer
• Check the electrodes and/or the ignition
•
transformer
• Dirty or badly adjusted ignition electrodes
• Clean and adjust the electrodes
• Lack of water in the hydraulic system
• Check the hydraulic system
• Fuel supply is insufficient
• Clean the diesel oil nozzle and/or the diesel oil
•
filter
• Diesel oil flow pressure is insufficient
• Calibrate the diesel oil pump or replace it
• Broken thermostat
• Replace the thermostat or request the intervention
•
of the assistance centre
• The heating pipe coil is clogged with calcareous
•
deposits
• Follow the instructions of the “Descaling”
•
paragraph
• When the gun is closed the burner is on
• The pressure switch does not work
• Request the intervention of the assistance centre
• Incorrect combustion
• Request the intervention of the assistance centre
• Presence of impurities in the fuel
• Empty the tank and carefully clean it
• Electrodes in incorrect position
• Request the intervention of the assistance centre
• Incorrect air adjustment
• Request the intervention of the assistance centre
• Dirty or worn diesel oil nozzle
• Clean or replace the nozzle
• Dirty diesel oil pump and/or filter
• Clean the diesel oil filter and/or the pump
• Broken solenoid valve
• Replace the solenoid valve
• The burner starts (ventilator is on), but the flame
•
is not lit
• The machine does not provide any detergent
• The adjustment valve is reset with the
•
actioning lever at rest
• No diesel oil is supplied
• Weak or absent ignition spark
• The water temperature does not reach the required
•
level
• Excessive smoke