- 18 -
INST
ALLA
TION
TECHNICAL INFORMATION
4.3 Technical data mod. Riva Plus
HE 24S ERP
Heat input
Nominal net
(A)
(ch - dhw)
kW
25,0
BTU/h 85304
Nominal gross
(B)
(ch - dhw)
kW
27,8
BTU/h 94687
Minimun net
(A)
ch - dhw
kW
7,5
BTU/h 25591
Minimun gross
(B)
ch - dhw
kW
8,3
BTU/h 28406
Useful output
Maximun (ch - dhw)
kW
24,4
BTU/h
83256
Minimun (ch - dhw)
kW
7,3
BTU/h 24909
Maximun condensing (ch - dhw)
kW
26,3
BTU/h 89739
Minimun condensing (ch - dhw)
kW
7,8
BTU/h 26615
Central heating
Min/Max flow temperature settings*
°C
50-85
Minimum return temperature
°C
40
Maximum pressure
kPa
250
bar
2,5
Minimum pressure
kPa
30
bar
0,3
Available head (in 1000 l/h)
kPa
25
bar
0,25
Seasonal efficiency G20
%
88,1
Seasonal effciency G30 G31
(C)
%
89,1
* to the minimum useful output
Gas supply pressures
Gas
Pa
mbar
Natural G20
Nom
2000
20
Min
1700
17
Max
2500
25
Butane G30
Nom
2900
29
Min
2000
20
Max
3500
35
Propane G31
Nom
3700
37
Min
2500
25
Max
4500
45
1 mbar approximately equals 10 mm H
2
O
Max. gas pressures at the burner
Natural G20
Pa
1340
mbar
13,4
Butane G30
Pa
2760
mbar
27,6
Propane G31
Pa
3550
mbar
35,5
Min. gas pressures at the burner
Natural G20
Pa
140
mbar
1,4
Butane G30
Pa
280
mbar
2,8
Propane G31
Pa
350
mbar
3,5
Ignition gas pressures at the burner
Natural G20
Pa
850
mbar
8,5
Butane G30
Pa
2110
mbar
21,1
Propane G31
Pa
2700
mbar
27,0
1 mbar approximately equals 10 mm H
2
O