![BGH GMV-1015WM/G-X Technical Sales Manual Download Page 93](http://html1.mh-extra.com/html/bgh/gmv-1015wm-g-x/gmv-1015wm-g-x_technical-sales-manual_2746748093.webp)
70%
-19.8
-20.0
47.1
18.59
47.1
19.09
44.4
18.02
42.8
17.63
41.1
17.23
38.5
16.46
-18.8
-19.0
47.7
18.68
47.6
19.08
44.5
17.89
42.8
17.51
41.1
17.10
38.5
16.12
-16.7
-17.0
48.5
18.58
47.9
18.74
44.5
17.48
42.9
17.10
41.2
16.64
38.5
15.38
-13.7
-15.0
49.5
18.49
48.0
18.36
44.6
17.05
43.0
139.12
41.3
15.86
38.5
14.62
-11.8
-13.0
50.3
18.35
48.0
17.83
44.6
16.28
43.0
15.71
41.3
15.04
38.5
13.87
-9.8
-11.0
51.3
18.14
48.0
17.17
44.7
15.42
43.0
14.87
41.3
14.24
38.5
13.13
-9.5
-10.0
51.5
17.89
48.1
16.68
44.7
14.98
43.0
14.45
41.4
13.85
38.5
12.77
-8.5
-9.1
51.5
17.63
48.1
16.23
44.7
14.59
43.0
14.08
41.4
13.50
38.5
12.45
-7.0
-7.6
51.4
16.80
48.0
15.47
44.6
13.94
43.0
13.46
41.3
12.90
38.5
11.92
-5.0
-5.6
51.1
15.69
47.7
14.47
44.3
13.06
42.7
12.60
41.3
12.15
38.5
11.25
-3.0
-3.7
51.1
14.78
47.7
13.64
44.3
12.34
42.7
11.90
41.3
11.49
38.5
10.64
0.0
-0.7
51.1
13.45
47.7
12.49
44.3
11.27
42.7
10.89
41.3
10.52
38.5
9.75
3.0
2.2
51.1
12.29
47.7
0.28
44.3
10.35
42.7
9.99
41.3
9.66
38.5
8.96
5.0
4.1
51.1
11.60
47.7
10.74
44.3
9.79
42.7
9.45
41.3
9.15
38.5
8.49
7.0
6.0
51.1
10.96
47.7
10.16
44.3
9.26
42.7
8.95
41.3
8.67
38.5
8.05
9.0
7.9
51.1
10.37
47.7
9.61
44.3
8.78
42.7
8.49
41.3
8.22
38.5
7.64
11.0
9.8
51.1
9.80
47.7
9.09
44.3
8.33
42.7
8.05
41.3
7.80
38.5
7.25
13.0
11.8
51.1
9.26
47.7
8.61
44.3
7.88
42.7
7.64
41.3
7.38
38.5
6.89
15.0
13.7
51.1
8.78
47.7
8.17
44.3
7.49
42.7
7.26
41.3
7.02
38.5
6.56
18.0
16.8
51.1
8.33
47.7
7.76
44.3
7.13
42.7
6.92
41.3
6.70
38.5
6.27
20.0
18.5
51.1
7.93
47.7
7.39
44.3
6.80
42.7
6.61
41.3
6.41
38.5
6.02
24.0
20.5
51.1
7.58
47.7
7.06
44.3
6.53
42.7
6.34
41.3
6.17
38.5
5.80
60%
-19.8
-20.0
43.9
18.44
41.0
17.63
38.1
15.98
36.7
15.33
35.5
14.81
33.1
13.66
-18.8
-19.0
43.9
18.30
41.0
17.41
38.1
15.66
36.7
15.03
35.5
14.49
33.1
13.37
-16.7
-17.0
43.9
17.85
41.1
16.71
38.2
14.97
36.7
14.37
35.5
13.85
33.1
12.79
-13.7
-15.0
44.0
17.27
41.1
15.90
38.3
14.28
36.8
13.71
35.5
13.19
33.1
12.18
-11.8
-13.0
44.0
16.35
41.1
15.06
38.3
13.55
36.8
13.02
35.5
12.53
33.1
11.59
-9.8
-11.0
44.1
15.47
41.2
14.26
38.3
12.86
36.9
12.35
35.5
11.87
33.1
10.99
-9.5
-10.0
44.1
15.04
41.2
13.88
38.3
12.51
36.9
12.03
35.5
11.55
33.1
10.69
-8.5
-9.1
44.1
14.65
41.2
13.52
38.3
12.21
36.9
11.73
35.5
11.26
33.1
10.44
-7.0
-7.6
44.0
13.98
41.1
12.92
38.3
11.67
36.8
11.22
35.5
10.80
33.1
10.02
-5.0
-5.6
43.8
13.09
40.9
12.10
38.0
10.96
36.6
10.53
35.5
10.20
33.1
9.48
-3.0
-3.7
43.8
12.36
40.9
11.43
38.0
10.41
36.6
9.98
35.5
9.67
33.1
8.97
0.0
-0.7
43.8
11.29
40.9
10.47
38.0
9.52
36.6
9.16
35.5
8.88
33.1
8.25
3.0
2.2
43.8
10.35
40.9
9.62
38.0
8.77
36.6
8.43
35.5
8.19
33.1
0.33
5.0
4.1
43.8
9.79
40.9
9.10
38.0
8.31
36.6
8.00
35.5
7.76
33.1
7.23
7.0
6.0
43.8
9.26
40.9
8.61
38.0
7.88
36.6
7.59
35.5
7.38
33.1
6.87
9.0
7.9
43.8
8.78
40.9
8.17
38.0
7.48
36.6
7.22
35.5
7.00
33.1
6.54
11.0
9.8
43.8
8.33
40.9
7.76
38.0
7.12
36.6
6.86
35.5
6.66
33.1
6.24
13.0
11.8
43.8
7.88
40.9
7.35
38.0
6.76
36.6
6.52
35.5
6.33
33.1
5.93
15.0
13.7
43.8
7.50
40.9
6.98
38.0
6.44
36.6
6.21
35.5
6.04
33.1
5.65
18.0
16.8
43.8
7.16
40.9
6.65
38.0
6.15
36.6
5.94
35.5
5.79
33.1
5.42
20.0
18.5
43.8
6.86
40.9
6.35
38.0
5.90
36.6
5.71
35.5
5.57
33.1
5.22
24.0
20.5
43.8
6.60
40.9
6.09
38.0
5.68
36.6
5.51
35.5
5.39
33.1
5.04
Co
m
binatio
n
Outdoor air
temp
Indoor air temperature
℃
DB
16
18
20
21
22
24
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
℃
DB
℃
WB
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
GMV6 DC Inverter VRF Units
Technical Sales Guide
91