Co
m
binatio
n
Outdoor air
temp
Indoor air temperature
℃
DB
16
18
20
21
22
24
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
℃
DB
℃
WB
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
90%
-19.8
-20.0
28.2
9.31
28.1
9.65
28.0
9.78
28.1
10.04
28.0
10.23
28.0
10.57
-18.8
-19.0
28.4
9.34
28.3
9.65
28.3
9.81
28.3
10.02
28.4
10.23
28.2
10.59
-16.7
-17.0
28.9
9.39
28.9
9.71
28.8
9.81
28.9
10.02
28.9
10.25
28.8
10.55
-13.7
-15.0
29.5
9.40
29.4
9.70
29.4
9.79
29.4
9.93
29.3
10.18
28.9
10.34
-11.8
-13.0
30.0
9.40
29.9
9.64
29.9
9.76
29.9
9.95
29.9
10.08
28.9
10.10
-9.8
-11.0
30.5
9.32
30.5
9.57
30.4
9.67
30.5
9.86
30.4
9.99
29.0
9.82
-9.5
-10.0
30.8
9.30
30.7
9.55
30.6
9.60
30.7
9.81
30.7
9.98
29.1
9.71
-8.5
-9.1
31.0
9.27
30.9
9.47
30.8
9.56
30.9
9.72
30.9
9.88
29.5
9.66
-7.0
-7.6
31.3
9.20
31.2
9.38
31.2
9.47
31.2
9.62
31.2
9.74
29.5
9.23
-5.0
-5.6
32.7
9.31
32.6
9.51
32.6
9.56
32.6
9.69
31.6
9.42
29.5
8.68
-3.0
-3.7
34.3
9.49
34.3
8.63
33.9
9.57
32.7
9.22
31.6
8.88
29.5
8.18
0.0
-0.7
37.1
9.76
36.0
8.47
33.9
8.70
32.7
8.38
31.6
8.07
29.5
7.44
3.0
2.2
38.2
9.30
36.0
8.66
33.9
7.93
32.7
7.65
31.6
7.37
29.5
6.81
5.0
4.1
38.2
8.74
36.4
8.23
33.9
7.48
32.7
7.21
31.6
6.96
29.5
6.42
7.0
6.0
39.0
8.40
36.4
7.75
33.9
7.05
32.7
6.81
31.6
6.57
29.5
6.07
9.0
7.9
39.0
7.91
36.4
7.30
33.9
6.65
32.7
6.43
31.6
6.20
29.5
5.74
11.0
9.8
39.0
7.45
36.4
6.88
33.9
6.29
32.7
6.08
31.6
5.86
29.5
5.44
13.0
11.8
39.0
7.01
36.4
6.49
33.9
5.93
32.7
5.74
31.6
5.54
29.5
5.13
15.0
13.7
39.0
6.63
36.4
6.13
33.9
5.62
32.7
5.42
31.6
5.25
29.5
4.87
18.0
16.8
39.0
6.26
36.4
5.79
33.9
5.34
32.7
5.12
31.6
4.98
29.5
4.63
20.0
18.5
39.0
5.92
36.4
5.47
33.9
5.07
32.7
4.83
31.6
4.73
29.5
4.43
24.0
20.5
39.0
5.59
36.4
5.17
33.9
4.81
32.7
4.56
31.6
4.49
29.5
4.23
80%
-19.8
-20.0
28.0
9.94
28.0
10.28
28.0
10.35
28.0
10.56
27.9
10.77
25.6
10.18
-18.8
-19.0
28.3
9.99
28.3
10.26
28.2
10.37
28.3
10.57
28.0
10.64
25.7
10.12
-16.7
-17.0
28.9
10.00
28.8
10.28
28.7
10.34
28.8
10.53
28.0
10.41
25.7
9.87
-13.7
-15.0
29.3
9.94
29.4
10.24
29.3
10.29
29.1
10.39
28.1
10.21
25.9
9.70
-11.8
-13.0
29.8
9.91
29.9
10.16
29.8
10.22
29.1
10.15
28.1
9.92
26.3
9.37
-9.8
-11.0
30.4
9.82
30.3
10.01
30.3
10.11
29.2
9.86
28.1
9.58
26.3
8.85
-9.5
-10.0
30.7
9.78
30.6
10.00
30.4
9.95
29.2
9.70
28.1
9.31
26.3
8.59
-8.5
-9.1
30.9
9.73
30.8
9.91
30.4
9.82
29.2
9.47
28.1
9.07
26.3
8.36
-7.0
-7.6
31.1
9.60
31.2
9.80
30.3
9.42
29.1
9.02
28.2
8.69
26.3
8.03
-5.0
-5.6
32.6
8.65
32.0
9.64
30.1
8.80
29.1
8.49
28.2
8.17
26.3
7.53
-3.0
-3.7
33.9
8.70
32.3
9.17
30.1
8.29
29.1
8.04
28.2
7.71
26.3
7.12
0.0
-0.7
33.9
8.85
32.3
8.32
30.1
7.56
29.1
7.30
28.2
7.03
26.3
6.50
3.0
2.2
34.7
8.25
32.3
7.59
30.1
6.91
29.1
6.67
28.2
6.44
26.3
5.96
5.0
4.1
34.7
7.77
32.3
7.16
30.1
6.52
29.1
6.30
28.2
6.09
26.3
5.63
7.0
6.0
34.7
7.32
32.3
6.77
30.1
6.16
29.1
5.96
28.2
5.76
26.3
5.33
9.0
7.9
34.7
6.91
32.3
6.37
30.1
5.86
29.1
5.63
28.2
5.44
26.3
5.05
11.0
9.8
34.7
6.53
32.3
6.02
30.1
5.52
29.1
5.33
28.2
5.15
26.3
4.79
13.0
11.8
34.7
6.15
32.3
5.69
30.1
5.22
29.1
5.04
28.2
4.87
26.3
4.53
15.0
13.7
34.7
5.82
32.3
5.39
30.1
4.95
29.1
4.78
28.2
4.63
26.3
4.31
18.0
16.8
34.7
5.55
32.3
5.12
30.1
4.71
29.1
4.55
28.2
4.39
26.3
4.11
20.0
18.5
34.7
5.34
32.3
4.91
30.1
4.51
29.1
4.34
28.2
4.18
26.3
3.92
24.0
20.5
34.7
5.18
32.3
4.75
30.1
4.32
29.1
4.15
28.2
3.99
26.3
3.76
72