background image

USER’S MANUAL

ENGLISH

Thank you for buying this product, our company is sure that you will be more than satisfied with the product’s performance. The product is supplied with a 

Warnings

” leaflet and an “

Instruction booklet

”. These should both be read carefully as they provide important information about safety, installation, ope-

ration and maintenance. This product complies with the recognised technical standards and safety regulations. We declare that this product is in conformity 
with the following European Directives: 89/336/EEC and 73/23/EEC (and subsequent amendments).

1) GENERAL OUTLINE

Suitable for motorising sectional doors , spring overhead doors with total reentrance  and overhead doors with counterweights by means of a special pulling 
arm. The maximum height of the overhead door must not exceed 2.5 meters (3.5 meters with extension).
The installation is carried out easily, it allows a fast assembly without any change to the door. The closing lock is maintained by the irreversible motor reducer. 
This product was designed in order to motorise the above mentioned types of doors. Any other use will be considered contrary to the use foreseen by the 
manufacturer which, therefore, cannot be considered responsible for any caused damage to things, people, animals.

2) SAFETY

If correctly installed and used, this automation device satisfies the required safety level standards. However, it is advisable to observe some practical rules 
in order to avoid accidental problems. Before using the automation device, carefully read the operation instructions and keep them for future reference.
•   Keep children, persons and things outside the automation working area, particularly during operation.
•   Keep radio control or other control devices out of children’s reach, in order to avoid any unintentional automation activation.
•   Do not intentionally oppose the leaf movement.
•   Do not attempt to open the door manually, if the internal locking system has not been released by pulling the appropriate wire connected to the carriage, 

or the external lock (

SM1 or SET/S

) activated.

•   Do not modify the automation components.
•   In case of malfunction, disconnect the power supply, activate the emergency release to gain access to the automation device and request the assistance 

of a qualified technician (installer).

•   Before proceeding to any external cleaning operation, disconnect the mains powers supply.
•   Keep the photocell optical components and luminous signal indication devices clean. Check that the safety devices (photocells) are not obscured by 

branches or shrubs.

•   For any direct assistance to the automation system, request the assistance of a qualified technician (installer).
•   Have qualified personnel check the automation system once a year.

3) EMERGENCY MANOEUVRE

In case of electric power failure or system malfunction, the manoeuvre must be carried out manually by pulling the wire connected to the carriage, as in fig.1. 
For garages which are not provided with a second exit, it is compulsory to fit an external key release device like Mod. 

SM1

 (fig.2) or Mod. 

SET/S

 (fig.3).

Fig. 1

Fig. 2

Fig. 3

4 -

 

TIR 60-120 - Ver. 05

D811162_05

Summary of Contents for TIR 120

Page 1: ...AUTOMAZIONI PER PORTE BASCULANTI E SEZIONALI AUTOMATION FOR OVERHEAD AND SECTIONAL GARAGE DOORS AUTOMATION POUR PORTES BASCULANTES ET SECTIONALES GARAGENTORANTRIEB F R SCHWING UND SEKTIONALTORE AUTOM...

Page 2: ...2 TIR 60 120 Ver 05 D811162_05...

Page 3: ...er to avoid accidental problems Before using the automation device carefully read the operation instructions and keep them for future reference Keep children persons and things outside the automation...

Page 4: ...tandard 2 TECHNICAL DETAILS Power supply 230V 10 50 60Hz Single phase Motor voltage 24V Motor power TIR60 180W TIR120 260W Absorption TIR60 0 7A TIR 120 0 9A Lubrication Permanent grease Traction and...

Page 5: ...of the opening microswit ches OPEN until hearing the click of the rst and second limit switch Lower the spring until tting a tooth of the cam Feed the system and give START to carry out the closing m...

Page 6: ...regulations In case of scrapping the automation devices do not entail any particular risks or danger In case of materials to be recycled these should be sorted out by type electrical components copper...

Page 7: ...Fig 7 Fig 5 Fig 6 Fig 8 G Fig 1 Fig 3 Fig 2 207 40 132 67 370 3350 2980 TIR 60 120 Ver 05 27 D811162_05...

Page 8: ...Fig 10 Fig 14 Fig 12 Fig 11 Fig 13 Fig 9 28 TIR 60 120 Ver 05 D811162_05...

Page 9: ...4x1mm 2x1mm LINEA 3x1 5mm JP5 TIR 60 2 Marrone Brown Brun Braun Marron Castanho 3 Grigio Gery Gris Grau Gris Cinza TIR 120 2 Jaune Jellow Jaune Gelb Amarillo Amarelo 3 Blu Blue Bleue Blau Azul Azul Es...

Page 10: ...Fig 18 Fig 19 Fig 21 Fig 17 Fig 20 30 TIR 60 120 Ver 05 D811162_05...

Page 11: ...Fig 25 Fig 26 Fig 23 Fig 24 Fig 22 TIR 60 120 Ver 05 31 D811162_05...

Reviews: