INSTALLATION MANUAL
Terminal
De
fi
nition
Description
Po
w
er
supply
L
LINE
Single-phase power supply
with earth cable
N
NEUTRAL
GND
EARTH
M
ot
or
10
START + CONDENSER
Motor and condenser connection
11
COM
12
START + CONDENSER
A
ux
20
AUX 0 – POWERED CONTACT
230V (N.O.) (40W MAX)
Exit due to FLASHING LIGHT
Contact stays closed while leaves are operating.
21
Limit
swit
ches
41
+REF SWE
Limit switch common
42
SWC
Closing limit switch SWC (N.C.)
43
SWO
Opening limit switch SWO (N.C.)
A
cc
essories
po
w
er supply
50
0V-
Accessories power supply output.
51
24V+
52
24 Vsafe+
Tested safety device power supply output (photocell transmitter and safety edge transmitter).
Output act ive only during operating cycle.
Commands
60
Common
START and OPEN inputs common
61
START
START command button (N.O.).
Operation according to “Residential / apartment building operation” logic
62
OPEN
OPEN command button (N.O.).
Gate opened with this command. If the input stays closed, the leaves stay open until the
contact is opened.
When the contact is open, the automated device closes following the TCA time, where
activated.
LED INDICATORS:
POWER
Steadily lit: - Mains power on - Board powered - Fuses intact
START
Lit: START input activated
OPEN
Lit: OPEN pedestrian input activated
STOP
Unlit: STOP input activated
PHOT
Unlit: PHOT photocell input activated
FAULT 1
PHOT input safety device test input diagnostics
BAR
Unlit: BAR safety edge input activated
FAULT 2
BAR input safety device test input diagnostics
SWC
Unlit: leaf fully closed
Lit: motor limit switch is disengaged
Flashing: end of the work time while closing
SWO
Unlit: leaf fully open
Lit: motor limit switch is disengaged
Flashing: end of the work time while opening
ERR
Unlit: no error
LIT: see error diagnostics table
RADIO
(GREEN)
Unlit: remote programming not active
Radio LED only
fl
ashing: Remote programming active, waiting for
hidden key.
Flashing in sync with Set LED: Transmitter deletion in progress
Lit: remote programming active, waiting for desired key.
Lit 1s: Radio receiver channel activated
SET
Lit: Set key pressed / Autoset completed successfully
Flashes three times: Autoset in progress
Fast
fl
ashing 10s: Autoset failed
Flashing in sync with Radio LED: Transmitter deletion in progress
Lit 1s: Start/Stop after key S3 pressed
Lit 10s: Autoset completed correctly
TABLE ERR
Led ERR
Lit
slow
fl
ashing
fast
fl
ashing
Led SE
T
Unlit
Photocell test,
Costa o Costa
8k2 failed
- Check photo-
cell connection
and/or logic
settings
Lit
Reverse due to
obstacle - Ampe-
rostop
- Check for obsta-
cles in path
Thermal cutout
- Allow automated
device to cool
slow
fl
ashing
Test hardware card
error
- Check the
connection to the
motor
- Hardware pro-
blems to the card
(contact technical
assistance)
Thermal
- Wait for the auto-
mation to cool
Changed settings
and/or Operating
logics press S2 for
5s to con
fi
rm.
24 -
SHYRA-F
D812434 00100_05
Summary of Contents for SHYRA AC F SL
Page 43: ...SHYRA F 43 D812434 00100_05 ...
Page 44: ...www bftme ae ...