ENGLISH
INSTALLATION MANUAL
Terminal
De
fi
nition
Description
Saf
et
y de
vic
es
70
Common
STOP, PHOT and BAR inputs common
71
STOP
The command stops movement. (N.C.)
If not used, leave jumper inserted.
72
PHOT (*)
PHOTOCELL input (N.C.).
Operation according to “PHOTOCELL/PHOTOCELL DURING CLOSING” logic. If not used, leave
jumper inserted.
73
FAULT 1
Test input for safety devices connected to PHOT.
74
BAR /
BAR CL /
BAR TEST /
BAR CL TEST /
BAR 8K2 /
BAR CL 8K2
(*)
Safety edge input (N.C.).
If not used, leave jumper inserted
BAR/8K2
dip
Safety edge
check
dip
Safety edge
operation
dip
OFF
OFF
OFF
NC input, no veri
fi
cation, reversal while
opening and closing
(BAR)
OFF
OFF
ON
NC input, no veri
fi
cation, reversal only when
closing, stop when opening
(BAR CL)
OFF
ON
OFF
NC input, with veri
fi
cation, reversal while
opening and closing
(BAR TEST)
OFF
ON
ON
NC input, with veri
fi
cation, reversal only
when closing, stop when opening
(BAR
CL TEST)
ON
OFF
OFF
8K2 input, reversal when opening and
closing
(BAR 8K2)
ON
OFF
ON
8K2 input, reversal only when closing, stop
when opening
(BAR CL 8K2)
75
FAULT 2
Test input for safety devices connected to BAR / BAR CL
A
nt
enna
Y
ANTENNA
Antenna input.
Use an antenna tuned to 433MHz. Use RG58 coax cable to connect the Antenna and Receiver.
Metal bodies close to the antenna can interfere with radio reception. If the transmitter’s
range is limited, move the antenna to a more suitable position.
#
SHIELD
(*) If “D” type devices are installed (as de
fi
ned by EN12453), connect in unveri
fi
ed mode, foresee mandatory maintenance at least every six months.
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
TABLE “A”
-
PARAMETERS
Any modi
fi
cation of parameters/logics must be con
fi
rmed by pressing S2 > 5s
TRIMMER
Parameter
+
min.
+
max.
+
default
Description
T1
Automatic
closing time [s]
0
120
0
Waiting time before automatic closing.
NOTE: Set to 0 if not used.
T2
Leaf strength [%]
1
100
50%
Force exerted by leaf/leaves.
ATTENTION: It directly a
ff
ects the impact force: check the set value
complies with the safety regulations in force(*). If necessary, install
anti-crushing safety devices.
T3
Not used
SHYRA-F
-
25
D812434 00100_
05
Summary of Contents for SHYRA AC F SL