ENGLISH
INSTALLATION MANUAL
Logic
Definition
Default
Cross out
setting
used
Optional extras
EXPI2
Configuration of
EXPI2 input
on input-output
expansion board.
1-3
0
0
Input configured as Start E command.
1
Input configured as Start I command.
2
Input configured as Open command.
3
Input configured as Close command.
4
Input configured as Ped command.
5
Input configured as Timer command.
6
Input configured as Timer Pedestrian command.
7
Input configured as Phot (photocell) safety.
8
Input configured as Phot op safety (photocell active during opening only).
9
Input configured as Phot cl safety (photocell active during closing only).
10
Input configured as Bar safety (safety edge).
EXPO1
Configuration of
EXPO2 output
on input-output
expansion board
4-5
1
1
Output configured as SCA (gate open light).
2
Output configured as Courtesy Light command.
3
Output configured as Zone Light command.
4
Output configured as Stair Light.
EXPO2
Configuration of
EXPO2 output
on input-output
expansion board
6-7
9
5
Output configured as Alarm.
6
Output configured as Flashing light.
7
Output configured as Latch.
8
Output configured as Magnetic lock.
9
Output configured as Maintenance.
10
Output configured as Flashing Light and Maintenance.
LEO B CBB 3 230 L01-
19
D811828 00100_02