ENGLISH
INSTALLATION MANUAL
2) GENERAL INFORMATION
The
LEO B CBB 3 230 L01
control panel comes with standard factory settings. Any
change must be made using the programmer with built-in display or universal
handheld programmer.
Its main features are:
- Control of 1 single-phase motor
- Electronic torque control with obstacle detection
- Separate inputs for safety devices
- Configurable command inputs
- ENCODER control input
The board has a terminal strip of the removable kind to make maintenance
or replacement easier. It comes with a series of prewired jumpers to make the
installer’s job on site easier.
The jumpers concern terminals: 70-71, 70-72, 70-74, 76-77.
If the above-mentioned terminals are being used, remove the relevant jumpers.
TESTING
The
LEO B CBB 3 230 L01
panel controls (checks) the start relays and safety
devices (photocells) before performing each opening and closing cycle.
If there is a malfunction, make sure that the connected devices are working
properly and check the wiring.
3) TECHNICAL SPECIFICATIONS
Power supply
230V~ ±10% 50Hz*
Low voltage/mains insulation
> 2MOhm 500V
Operating temperature range
-10 / +55°C
Thermal overload protection
built into motor
Dielectric rigidity
mains/LV 3750V~ for 1 minute
Maximum motor power
750W
Accessories power supply
24V~ (demand max. 180mA)
24V~safe (demand max. 180mA)
AUX 3
NO contact (24V~/max.3W)
Flashing light
230V~ 40W max
Dimensions
see
Fig. A
Fuses
see
Fig. B
Protection rating
IP54
(*other voltages to order)
4) TERMINAL BOARD WIRING Fig. B
Terminal
Definition
Description
Po
w
er
supply
L
LINE
Single-phase power supply 230V~ ±10%, 50-60Hz, with earth cable
N
NEUTRAL
gND
EARTH
M
ot
or
10
OPEN1 + CAP1
Motor connection.
OPEN1 + CAP1 Opening Motor and capacitor
COM1 Motor Common
CAP1 Closing Motor and capacitor
11
COM1
12
CAP1
Au
x
20
LIgHT 230V
Flashing light 230V output max. 40W.
21
26
AUX 3 - FREE
CONTACT (N.O.)
(Max. 24V 3W)
Contact N.O. (24V~/3W max).
Can only be used with second channel of radio-receiver plugged into relevant connector.
27
ENC
ODER
40
- REF SWE
ENCODER power supply
41
+ REF SWE
42
A RS485
ENCODER communication
43
B RS485
A
cc
essories
po
w
er supply
50
24V-
Accessories power supply output.
51
24V+
52
24 Vsafe+
Tested safety device power supply output (photocell transmitter and safety edge transmitter).
Output active only during operating cycle.
Commands
60
Common
IC 1 and IC 2 inputs common
61
IC 1
Configurable command input 1 (N.O.) - Default START E.
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the “Command input configuration” table.
62
IC 2
Configurable command input 2 (N.O.) - Default PED.
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the “Command input configuration” table.
63
Common
IC 3 and IC 4 inputs common
64
IC 3
Configurable command input 3 (N.O.) - Default OPEN.
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the “Command input configuration” table.
65
IC 4
Configurable command input 4 (N.O.) - Default CLOSE.
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the “Command input configuration” table.
Saf
et
y de
vic
es
70
Common
STOP, SAFE 1 and SAFE 2 inputs common
71
STOP
The command stops movement. (N.C.)
If not used, leave jumper inserted.
72
SAFE 1
Configurable safety input 1 (N.C.) - Default PHOT.
PHOT / PHOT TEST / PHOT OP / PHOT OP TEST / PHOT CL / PHOT CL TEST / BAR / BAR TEST / BAR 8K2
Refer to the “Safety input configuration” table.
73
FAULT 1
Test input for safety devices connected to SAFE 1.
74
SAFE 2
Configurable safety input 2 (N.C.) - Default BAR.
PHOT / PHOT TEST / PHOT OP / PHOT OP TEST / PHOT CL / PHOT CL TEST / BAR / BAR TEST / BAR 8K2
Refer to the “Safety input configuration” table.
75
FAULT 2
Test input for safety devices connected to SAFE 2.
76
Common
SAFE 3 input common
77
SAFE 3
Configurable safety input 3 (N.C.) - Default PHOT OP.
PHOT / PHOT TEST / PHOT OP / PHOT OP TEST / PHOT CL / PHOT CL TEST / BAR / BAR TEST
Refer to the “Safety input configuration” table.
78
FAULT 3
Test input for safety devices connected to SAFE 3.
A
nt
enna
Y
ANTENNA
Antenna input.
Use an antenna tuned to 433MHz. Use Rg58 coax cable to connect the Antenna and Receiver. Metal bodies close to the antenna
can interfere with radio reception. If the transmitter’s range is limited, move the antenna to a more suitable position.
#
SHIELD
LEO B CBB 3 230 L01-
15