ENGLISH
Logic
Definition
Default
Cross out
setting
used
Optional extras
EXPI1
Configuration of
EXPI1 input on
input-output expan-
sion board.
1-2
1
0
Input configured as Start E command.
1
Input configured as Start I command.
2
Input configured as Open command.
3
Input configured as Close command.
4
Input configured as Timer command
5
Input configured as Timer command.
6
Input configured as Timer Pedestrian command
7
Input configured as Phot (photocell) safety.
8
Input configured as Phot op safety (photocell active during opening only).
9
Input configured as Phot cl safety (photocell active during closing only).
10
Input configured as Bar safety (safety edge).
11
Input configured as Phot test safety (tested photocell).
Input 3 (EXPI2) on input/output expansion board is switched automatically to safety device test
input, EXPFAULT1.
12
Input configured as Phot op test safety (tested photocell active during opening only).
Input 3 (EXPI2) on input/output expansion board is switched automatically to safety device test
input, EXPFAULT1.
13
Input configured as Phot cl test safety (tested photocell active during closing only).
Input 3 (EXPI2) on input/output expansion board is switched automatically to
safety device test input, EXPFAULT1.
14
Input configured as Bar safety (tested safety edge).
Input 3 (EXPI2) on input/output expansion board is switched automatically to
safety device test input, EXPFAULT1.
EXPI2
Configuration of
EXPI2 input
on input-output
expansion board.
1-3
0
0
Input configured as Start E command.
1
Input configured as Start I command.
2
Input configured as Open command.
3
Input configured as Close command.
4
Input configured as Timer command
5
Input configured as Timer command.
6
Input configured as Timer Pedestrian command
7
Input configured as Phot (photocell) safety.
8
Input configured as Phot op safety (photocell active during opening only).
9
Input configured as Phot cl safety (photocell active during closing only).
10
Input configured as Bar safety (safety edge).
EXPO1
Configuration of
EXPO2 output
on input-output
expansion board
4-5
11
0
Output configured as 2
nd
Radio Channel.
1
Output configured as SCA (gate open light).
2
Output configured as Courtesy Light command.
3
Output configured as Zone Light command.
4
Output configured as Stair Light.
5
Output configured as Alarm.
EXPO2
Configuration of
EXPO2 output
on input-output
expansion board
6-7
11
6
Output configured as Flashing light.
7
Output configured as Latch.
8
Output configured as Magnetic lock.
9
Output configured as Maintenance.
10
Output configured as Flashing Light and Maintenance.
11
Output configured as Traffic Light control with TLB board.
12
output configured as barrier status
TRAFFIC LIGHT
PREFLASHING
Traffic light
pre-flashing
0
0
Pre-flashing switched off.
1
Red lights flash, for 3 seconds, at start of operation.
TRAFFIC LIGHT
RED LA P
ALWAYS ON
Steadily lit red light
0
0
Red lights off when gate closed.
1
Red lights on when gate closed.
TABLE “C” – RADIO MENU (
RADIO
)
Logic
Description
Add start
Add Start Key
associates the desired key with the Start command
add 2ch
Add 2ch Key
associates the desired key with the 2nd radio channel command.
erase 64
Erase List
WARNING!
Erases all memorized transmitters from the receiver’s memory.
Read receiver code
Displays receiver code required for cloning transmitters.
ON =
Enables remote programming of cards via a previously memorized W LINK transmitter.
It remains enabled for 3 minutes from the time the W LINK transmitter is last pressed.
OFF=
W LINK programming disabled.
GIOTTO BT A ULTRA 36 -
33
D814017 2F
A00_02
Summary of Contents for GIOTTO BT A ULTRA 36