Diagnostics
code
DESCRIPTION
NOTES
STRE
START E external start input activated
STRI
START I internal start input activated
OPEN
OPEN input activated
CLS
CLOSE input activated
TI E
TIMER input activated
STOP
STOP input activated
PHOT
Activation of PHOT photocell input or, if configured as verified
photocell, Activation of the associated FAULT input
PHOP
Activation of PHOT OP opening photocell input or, if configured
as active verified photocell only when opening, Activation of
the associated FAULT input
PHCL
Activation of PHOT CL closing photocell input or, if configured
as active verified photocell only when closing, Activation of
the associated FAULT input
BAR
Activation of BAR safety edge input or, if configured as verified
safety edge, Activation of the associated FAULT input
BAR 2
Activation of BAR safety edge input on slave motor (opposing
door connection) or, if configured as verified safety edge,
Activation of the associated FAULT input
SWC
SWC motor closing limit switch input activated
SWO
SWO motor opening limit switch input activated
refo
Enabling input reference opening
refc
Enabling input reference closing
ER01
Photocell test failed
Check photocell connection and/or logic settings
ER02
Safety edge test failed
Check safety edge connection and/or logic settings
ER03
Opening photocell test failed
Check photocell connection and/or parameter/logic setting
ER04
Closing photocell test failed
Check photocell connection and/or parameter/logic setting
ER05
Safety edge test on slave motor failed (opposite leaves
connection)
Check safety edge connection and/or parameter/
logic settings
er06
8k2 safety edge test failed
Check safety edge connection and/or parameter/
logic settings
ER1x
*
Board hardware test error
-Check connections to motor
-Hardware problems with board (contact technical
assistance)
ER2x
*
*
Encoder error
Check the cable, the encoder card and the motor direc-
tion (if necessary) and reset the card
ER3x
*
Reverse due to obstacle - Amperostop
Check for obstacles in path
ER4x
*
Thermal cutout
Allow automated device to cool
ER5x
*
Communication error with remote devices
Check connection with serial-connected accessory
devices and/or expansion boards
ER70, ER71
ER74, ER75
Internal system supervision control error.
Try switching the board off and back on again. If the
problem persists, contact the technical assistance
department.
ER72
Consistency error of the control unit’s parameters (Logics
and Parameters)
Pressing OK the detected settings are confirmed. The
board will keep on working with the detected settings.
The board settings must be checked (Parameters
and Logics)
ER73
D-track parameter error
Pressing OK, the board will keep on working with D-
track as a default.
An autoset is required
ErFx
*
limit switch error
Check limit switch connections
ERf3
Error in setting the SAFE inputs
Check if the SAFE inputs are correctly set; during the
operation of opposed barriers, SAFE2 must be set up
as safety edge. Fig. L
*
X
= 0,1,…,9,A,B,C,D,E,F