- 32 -
Control unit
EN
- Connect the
N.O.
contact of the
S1
loop receiver to input
PDM.
- Connect the
N.O.
contact of the
S2
loop receiver to input
CLOSE.
- The dimensional values of the loops are only approximate.
We suggest installing the “
MAK-2
” metal mass detector.
*
ENGLISH
DIMENSIONS
This solution is recommended when you want to enter a reserved area in just one direction activating a recognition command (radio control,
proximity key, magnetic keys, etc.).
The vehicle approaches the
reserved area.
When the vehicle is on loop
S1
the
device will move down only after a
recognition command.
If the device is moving back up and
you want to lower it again the ve-
hicle must be on loop
S1
and then
you must activate the recognition
command.
When the vehicle is no longer
on loop
S2
the device will move
back up.
Loops S1 and S2 also have a safety function in that they will not let the device move all the time the vehicle is on top.
ONE DIRECTION
ONE DIRECTION
ONE DIRECTION
ONE DIRECTION
12. EXAMPLES OF CONTROLLING ENTRANCES
12.1
INSTALLATION A
CONTROLLED ENTRANCE OR EXIT
PARAMETER
DATA
DESCRIPTION
The close command acts as a release closing and safety function.
Radio channel 1: Open
Opening consent