SECTION 4
MAINTENANCE
Servicing Notes
Servicing should be carried out annually by a competent person such as a GAS
SAFE registered engineer.
This is a condition of the guarantee schemes.
The service should include visually checking the chimney and fire opening for
accumulations of debris and a smoke test to check for a positive up-draught in the
chimney. To access the debris collection void a removeable plate is positioned on
the rear face of the firebox box behind the burner. The oxy-pilot on the burner unit
must also be changed as a condition of the guarantee. The condition of the
fuel-bed should be checked and
if necessary the whole item should be
replaced with a genuine replacement item.
The burner assembly is designed to
be removed as a complete unit for ease of access.
After any servicing work a
gas tightness check must always be carried out.
4.1
Removing the burner assembly from the fire.
4.1.1
Prepare work area (lay down dust sheets etc.)
4.1.2
Remove the glass assembly, remove the vermiculite and logs.
4.1.3
Isolate the gas supply and remove the supply pipe from the appliance
inlet elbow. Remove the two off screws which hold the burner in position
& then loosen injector screw, lift burner unit clear. Remove gas supply
cover plate held in position by two screws and isolate gas supply.
Remove six off screws and burner controls assembly can be lifted clear.
Take care not to damage battery pack or on/off switch and wiring.
4.1.4
To refit the burner assembly, locate the burner controls assembly and
refit the six off screws. Refit the burner via two off screws and
re-tighten the injector retaining screw. Refit the gas supply pipe and
carry out a gas tightness test. Refit the fuel-bed referring to section 3
for the correct log positions. Re-fit the glass panel.
4.2
Removing the gas control valve from the fire.
4.2.1
Remove the burner from the combustion chamber as described in
section 4.1 above.
4.2.2
Disconnect the inlet, outlet, pilot pipes and thermocouple connection
from the control valve.
4.2.3
Replace in reverse order and carry out a gas tightness test.