Safety
2-6
2.5.2
Electrical / electronic devices
Danger to life caused by electrical current!
Contact with live wires or components presents a danger
to life !
Prior to any work on the electrical equipment, disconnect
the flame amplifiering system from the power supply net-
work !
In keeping with the electrical regulations, work on electri-
cal / electronic parts / components may only be carried
out by electrical specialists.
Important rules of conduct
•
Check the device in regular intervals. Any defects or
faults ascertained have to be corrected immediately.
Switch off the device until the defects have been cor-
rected.
•
Equipment parts undergoing inspection, maintenance
or repair work have to be made de-energised, if re-
quired. First check that the disconnected parts are no
longer live, then short to earth. Also isolate neighbour-
ing live parts
•
If work is required on live parts, a second person has
to be assigned who can disconnect the power supply in
case of an emergency. Only use insulated tools !
•
Fuses must not be repaired or bridged. Only use origi-
nal fuses with the specified current !
Summary of Contents for 2.0GT
Page 2: ...ii...
Page 20: ......
Page 26: ...Technical data 3 6...
Page 38: ...Description 5 2...
Page 40: ......
Page 42: ...Maintenance and servicing 7 2...
Page 44: ...Failures 8 2...
Page 46: ...Order data 9 2...