background image

23

MOD.

 BEZZERA BZ10

4 - MACHINE INSTALLATION

4.1 Warnings

Installation must be carried out by qualified staff, 

according  to  the  instructions  supplied  by  the 

manufacturer and in compliance with applicable 

Laws.

The  machine  should  be  located  and  installed 

in a place where the use and maintenance are 

performed by qualified personnel. Can be used 

the  machine  in  places  used  to  staff  kitchen  ar-

eas in shops, offices and other working enviro-

ments; farm houses; by clients in hotels, motels 

and other residential type enviroments; bed and 

breakfast type enviroments

4.2 Preparation of the plant for in-

stallation

Prepare the machine’s support on a flat horizontal, 

dry, smooth, sturdy, stable surface positioned at 

such a height that the cup warming surface is over 

150 cm from the ground.

Do  not  use  water  jets,  neither  perform  the 

installation in places where water jets are used.

In order to guarantee regular operation, the device 

must be installed in places where the temperature 

is  between  +5°C  and  +32ºC  and  the  humidity 

does not exceed 70%.

If the machine is exposed to temperatures below 

+ 0°C, proceed as follows:

-  ensure that the machine has elapsed 24 hours 

in a place where temperature is higher than + 

15°C before turn it on.

The  machine  is  powered  electrically  and  needs 

the following to function:

-  connection to the electrical power circuit

4.2.1  Connection  to  the  electrical 

power circuit

Warnings:

-   The connection to the mains electricity supply 

shall be executed by qualified personnel.

-   The  system  shall  be  set  in  compliance  with 

existing Standards and grounded.

The  machine  is  supplied  with  power  cable 

equipped with plug; in the permanent connection 

to mains electricity supply, between the machine 

and  the  power  mains,  interpose  a  protection 

omnipolar switch, with minimum opening between 

overvoltage-category III contacts, proportional to 

the charge and in compliance with Standards in 

force.

4.3 Equipotential connection 

(Fig. 08)

This  connection,  prescribed  by  some  Standards, 

has  the  function  to  avoid  differences  of  electric 

potential  among  the  masses  of  the  machines 

installed in the same room. This machine is preset 

with a clamp placed under the base to connect an 

external wire, with eyelet terminal to be inserted 

between  the  two  nuts,  with  nominal  section  in 

compliance with Standards in force.

5 - MACHINE USE

5.1  First  machine  start  and  water 

loading in the boiler

Pour  water  into  the  tank,  checking  that  the 

aspiration pipe touches the bottom (Fig. 03).

Warnings:

-  Use water at ambient temperature

Insert the plug in the electrical socket.

Turn the main switch (Fig. 01; pos. 1) to position 1, 

green light (Fig. 01; pos. 2) turn ON.

Water is automatically loaded into the boiler.

A safety device will interrupt the motor-

pump after 120 seconds if the maximum 

water level is not reached in the boiler.

To restore working mode, turn off and turn on the 

machine again.

5.2 Heating

In  order  for  the  machine  to  reach  the  right 

temperature,  with  the  pressure  indicated  on  the 

boiler gauge (Fig. 01; pos. 11) between 1 and 1.2 

bar (0.1 - 0.12 MPa), open the steam tap (Fig. 01; 

pos. 9) and discharge the steam 2 or 3 times into 

Summary of Contents for BZ10

Page 1: ...BZ10 Manuale di istruzioni Instruction manual Manuel d instructions Bedienungsanleitung Manual de instrucciones IT EN FR DE ES Dal 1901 1 0...

Page 2: ......

Page 3: ...language in any form or with any means be they electronic mechanical magnetic optical chemical manual or other without the previous written authorisation of G BEZZERA 2010 G BEZZERA Tous droits r serv...

Page 4: ...4 MOD BEZZERA BZ10 FIG 02 FIG 01 C B A 2 1 9 10 11 3 4 7 8 5 6 12 1 0 1 0...

Page 5: ...5 MOD BEZZERA BZ10 FIG 03 a FIG 04 1 0...

Page 6: ...6 MOD BEZZERA BZ10 FIG 06 FIG 05 FIG 07 FIG 08 FIG 09 13 14 15 FIG 10 A B Stop ON ON...

Page 7: ...anzia non verr in nessun caso riconosciuta in presenza di macchine con sigillo rimosso o rovinato Il riconoscimento della garanzia da intendersi previa verifica del tecnico specializzato ed autorizzat...

Page 8: ...he seal The warranty shall never be granted in case of machine with removed or damaged seal Warranty will be granted only after verification by the G BEZZERA specialized authorized technician who will...

Page 9: ...reconnue en cas de machines priv es de ce seau ou en cas de seau endommag La validit de la garantie sera reconnue apr s v rification pr alable du technicien sp cialis et autoris G BEZZERA qui valuera...

Page 10: ...en oder besch digt werden Bei Maschinen deren Siegel entfernt oder besch digt ist wird keinerlei Garantie gew hrt Die Garantie wird erst nach der Pr fung durch eine spezielle von G BEZZERA autorisiert...

Page 11: ...a garant a no se reconocer en ning n caso en presencia de m quinas con el sello retirado o deteriorado El reconocimiento de la garant a debe entenderse previa verificaci n del t cnico especializado y...

Page 12: ...to per l installazione 15 4 2 1 Allacciamento alla rete elettrica 15 4 3 Collegamento equipotenziale 15 5 USO DELLA MACCHINA 5 1 Accensione della macchina e carico acqua in caldaia 15 5 2 Riscaldament...

Page 13: ...sullo scaldatazze con la parte cava rivolta verso l alto La macchina non destinata ad essere utilizzata all aperto Il simbolo seguente indica pericolo di ustioni 1 2 Uso previsto La macchina per caff...

Page 14: ...a elettricamente che permette il passaggio dell acqua per l infusione del caff 3 2 Descrizione dei comandi Fig 01 Fig 09 1 Interruttore generale 2 Spia verde 3 Spia gialla 4 Pulsante erogatore caff 5...

Page 15: ...mpianto deve essere realizzato in conformit alle Leggi vigenti e dotato di messa a terra La macchina viene fornita di cordone di alimen tazione provvisto di spina nel collegamento per manente alla ret...

Page 16: ...regolare funzionamento della macchina se spenta segnala l insufficiente livello di acqua nel serbatoio 5 3 Preparazione del caff 1 Togliere il portafiltro Fig 01 pos 6 dal gruppo erogatore Fig 01 pos...

Page 17: ...tazze e della vaschetta di scarico usare acqua Per il lavaggio del serbatoio dopo averlo estratto utilizzare acqua e detergenti neutri ed effettuare un accurato risciacquo Reinserire il serbatoio e r...

Page 18: ...co del portafiltro una volta serrato sul gruppo risulta pi spostato a destra del solito La guarnizione sottocoppa usurata Chiamare un tecnico specia lizzato per la sostituzione del la guarnizione sott...

Page 19: ...del vapore Fig 01 pos 9 la pressione della caldaia scender a zero ci cause r l innesto della resistenza e l aumento della temperatura Effettuare quest operazione quotidianamente all accen sione della...

Page 20: ...e plant for installation 23 4 2 1 Connection to the electrical power circuit 23 4 3 Equipotential connection 23 5 MACHINE USE 5 1 First machine start and water loading in the boiler 23 5 2 Heating 23...

Page 21: ...r systems must be set up carefully by the user according to what indi cated in chapter 4 of this Machine installation booklet The installer cannot absolutely modify the exist ing system set up by the...

Page 22: ...means of a valve electronically controlled 3 2 Description of controls Fig 01 Fig 09 1 Main switch 2 Green light 3 Yellow light 4 Coffee distribution button 5 Distribution unit 6 Filter holder 7 Water...

Page 23: ...ll be executed by qualified personnel The system shall be set in compliance with existing Standards and grounded The machine is supplied with power cable equipped with plug in the permanent connection...

Page 24: ...rtional to the opening of the tap the more the tap is opened the more steam will be distributed 4 Once steam has been distributed release knob remove liquid container and clean the steam nozzle immedi...

Page 25: ...ctric line again Use water to wash the cup holding grid and the drain basin Use water and neutral detergents to clean the tank after removing it When finished rinse thoroughly Replace the tank and ins...

Page 26: ...the unit the filter hold er handle is further to the right than usual The seal under the cup is worn Call a specialised technician to replace the seal under the cup Coffee flow is less than usual Cof...

Page 27: ...open the steam tap Fig 01 pos 9 the boiler pressure will go down to zero and this will cause the resistance to step in and increase the temperature Carry out this operation daily when turning on the m...

Page 28: ...lation pour la mise en place 31 4 2 1 Branchement l installation lectrique 31 4 3 Branchement quipotentiel 31 5 UTILISATION DE LA MACHINE 5 1 Mise en marche de la machine et remplissage d eau dans la...

Page 29: ...1 AVERTISSEMENTS 1 1 Avertissements g n raux Les installations lectriques et hydrauliques doi vent tre r alis es par l utilisateur conform ment aux indications du chapitre 4 du pr sent manuel Install...

Page 30: ...e passage de l eau pour l infusion du caf 3 2 Description des commandes Fig 01 Fig 09 1 Interrupteur g n ral 2 Voyant vert 3 Voyant jaune 4 Bouton de distribution du caf 5 Groupe de distribution 6 Por...

Page 31: ...rique Avertissements Le branchement au r seau lectrique doit tre effectu par du personnel qualifi L installation doit tre r alis e conform ment aux Lois en vigueur et dot e de mise la ter re La machin...

Page 32: ...s la vapeur dans le bac de r cup ration Si le voyant jaune Fig 01 pos 3 est allum cela indique que la machine fonctionne correcte ment s il est teint il indique que le niveau d eau dans le r servoir e...

Page 33: ...surfaces avant de re connecter la machine la ligne lectrique Pour le lavage de la grille sur laquelle les tasses se trou vent et de la cuve d vacuation utiliser de l eau Apr s avoir extrait le r serv...

Page 34: ...serr sur le groupe s av re tre d cal droite par rapport l emplacement habituel Le joint cr pine est us Appeler un technicien sp cialis pour le remplacement du joint cr pine Le d bit de caf est fai bl...

Page 35: ...pression de la chaudi re descendra z ro ce qui provoquera le d clenchement de la r sis tance et l augmentation de la temp rature Effectuer cette op ration tous les jours au moment de la mise en mar ch...

Page 36: ...2 Anlage f r die Installation vorbereiten 39 4 2 1 An die Stromversorgung anschlie en 39 4 3 Potenzialausgleich 39 5 BEDIENUNG DER MASCHINE 5 1 Einschalten der Maschine und F llen des Wassertanks 39...

Page 37: ...it der hohlen Seite nach oben auf den Tassenw rmer stellen Die Maschine ist nicht f r den Einsatz im Freien bestimmt Das folgende Symbol verweist auf Verletzungsgefahr durch Verbre 1 2 Vorgesehener Ei...

Page 38: ...esteuertes Ventil erm glicht den Durchfluss des Wassers f r die Ausgabe des Kaffees 3 2 Beschreibung der Funktionstasten Abb 01 Abb 09 1 Netzschalter 2 Gr ne Kontrollanzeige 3 Gelbe Kontrollanzeige 4...

Page 39: ...ng anschlie en Hinweise Der Anschluss an das Stromnetz muss durch qualifizierte Fachleute durchgef hrt werden Die Anlage muss nach den geltenden gesetzli chen Vorschriften eingerichtet werden und ber...

Page 40: ...hen des Hebels bleibt der Hahn ge ffnet Abb 05 Die Menge des austretenden Dampfs h ngt von der ffnung des Dampfhahns ab Je weiter der Hahn ge ff net wird um so mehr Dampf wird ausgegeben 4 Wenn gen ge...

Page 41: ...omnetz an schlie t Das Abstellgitter f r die Tassen und das Auffangbecken mit Wasser waschen Zum Reinigen des Tanks nach der Entnahme Wasser und neutrale Reinigungsmittel verwenden und sorg f ltig abs...

Page 42: ...an der Br hgruppe ist verschlissen Wenden Sie sich an einen Wartungstechniker f r den Austausch der Dichtung Es wird nur sehr wenig Kaffee ausgegeben Der Kaffee tritt tropfenweise aus die Ausgabezeit...

Page 43: ...den Dampfhahn Abb 01 Pos 9 Auf diese Weise senkt sich der Kesseldruck auf null was dazu f hrt dass sich der Widerstand einschaltet und die Temperatur steigt F hren Sie diesen Arbeitsschritt t glich be...

Page 44: ...ara la instalaci n 47 4 2 1 Conexionado con la red el ctrica 47 4 3 Conexi n equipotencial 47 5 USO DE LA M QUINA 5 1 Encendido de la m quina y carga del agua en la caldera 47 5 2 Calentamiento 47 5 3...

Page 45: ...o sumo cuatro cajas 1 ADVERTENCIAS 1 1 Advertencias generales Los equipos el ctricos e hidr ulicos deben ser preparados por el usuario de conformidad con lo indicado en el cap tulo 4 del presente manu...

Page 46: ...da el ctricamente permite el paso del agua para la infusi n del caf 3 2 Descripci n de los mandos Fig 01 Fig 09 1 Interruptor general 2 Piloto verde 3 Piloto amarillo 4 Bot n suministro caf 5 Grupo de...

Page 47: ...r realizarse respetando las Leyes vigentes y deber disponer de la puesta a tierra La m quina se suministra con un cable de ali mentaci n provisto de enchufe en la conexi n permanente a la red entre el...

Page 48: ...ltar el mando quitar el recipiente del l quido y lim piar inmediatamente con un pa o h medo el tubo del vapor eliminando los residuos del l quido calentado Advertencia No tocar directamente el tubo de...

Page 49: ...on otros residuos comerciales tenerse de intentar repararla por propia cuenta y acudir inmediatamente al servicio t cnico Si se da a el cord n de alimentaci n el ctrica apa gar inmediatamente la m qui...

Page 50: ...ro una vez apretado en el grupo resulta m s desplazado hacia la derecha que de costumbre La junta debajo de la copa est gastada Llamar a un t cnico especia lizado para que cambie la junta debajo de la...

Page 51: ...brir el grifo del vapor Fig 01 pos 9 la presi n de la caldera bajar a cero esto causar la activaci n de la resistencia y el aumento de la temperatura Efectuar esta operaci n a diario al encen der la m...

Page 52: ...NOTE...

Page 53: ...NOTE...

Page 54: ...NOTE...

Page 55: ......

Page 56: ...4 05 ed 06 13 rev 00 G BEZZERA MACCHINE PER CAFFE ESPRESSO Via Luigi Bezzera 1 20088 Rosate Milano Italy Tel 39 02 90848102 r a Telefax 39 02 90870287 Web www g bezzera it e mail commerciale bezzera i...

Reviews: