background image

BewellConnect - BW-GL1 - User Manual - 022017v1

BewellConnect - BW-GL1 - User Manual - 022017v1

8

9

KEEP THESE INSTRUCTIONS IN A SAFE PLACE.

2. INFORMATION

Important Information

•  If your blood glucose results are lower or higher than usual, and you do not have any 

symptoms of illness, first repeat the test. 

•  If you have symptoms or continue to get results which are higher or lower than usual, 

follow the treatment advice of your healthcare professional.

•  Use only fresh capillary whole blood samples to test your blood glucose. Using other sub-

stances will lead to incorrect results.

•  If you are experiencing symptoms that are inconsistent with your test results and you 

have followed all the instructions given in this owner’s manual, contact your healthcare 

professional.

Contrindications

The blood glucose measurement performed from a capillary blood sample can be unreli-

able in people with a  reduced peripheral blood circulation:

•  Severe dehydration and excessive water loss may cause readings which are lower than ac-

tual values. If you believe you are suffering from severe dehydration, consult a healthcare 

professional immediately.

•  Hyperglycemia accompanied by hyperosmolarity may have a negative effect on the glu-

cose measurements in the peripheral blood.

•  Severely hypotensive individuals or patients in shock may also affect the glucose mea-

surements in the peripheral blood. Please consult the healthcare professional before use

•  Patients suffering from decompensated heart failure NYHA Class IV or peripheral arterial 

occlusive disease should also consult a healthcare professional before use this device.

•  The measurement unit used for indicating the concentration of blood or plasma glucose 

can either have a weight dimension (mg/dL) or a molarity (mmol/L). The approximate cal-

culation rule for conversion of mg/dL in mmol/L is: 

mg/dL

Divided by 18

= mmol/L

mmol/L

Times 18

= mg/dL

For example:

1) 120 mg/dL ÷ 18 = 6.6 mmol/L

2) 7.2 mmol/L x 18 = 129 mg/dL approximately.

3. PLASMA GLUCOSE TARGETS FOR PEOPLE WITH DIABETES
The American Diabetes Association suggests the following targets for most nonpregnant 

adults with diabetes:

- A1C (also called glycosylated hemoglobin A1c, HbA1c or glycohemoglobin A1c): <7%

- Before a meal (preprandial plasma glucose): 80–130 mg/dl

- 1-2 hours after beginning of the meal (Postprandial plasma glucose): Less than 180 mg/dl 

Source: American Diabetes Association (2016). Checking Your Blood Glucose. 

More or less stringent glycemic goals may be appropriate for each individual. Please con-

sult your doctor to determine a target range that works best for you.

METER OVERVIEW

Front

Top

Right Side

Left Side

Back

1

2
3

5

6

7

9

8

10

4

1-  Test Strip Ejector

 

Eject the used strip by 

pushing up this button.

2-  Test Strip Slot

 

Insert test strip here to turn 

the meter on for testing.

3-  Bluetooth Indicator

4-  Display Screen

5-  Main Button (M) 

Enter the meter memory and 

silence a reminder alarm.

6-  Repeat Button (REPEAT)

 

Confirm the meter settings. 

7-  Up Button (UP)

8-  SET Button (S) 

Enter the meter settings.

9- Down Button (DOWN)

10- Battery Compartment

Summary of Contents for MyGluco BW-GL1

Page 1: ...ord Am ricain European market March Europ en BEWELLCONNECT CORP 185 Alewife Brook Parkway 410 CAMBRIDGE MA 02138 USA support bewell connect com www bewell connect com VISIOMED GROUP SA 112 Avenue Kl b...

Page 2: ...te Num ro de lot SN Serial number N mero de serie Num ro de s rie Caution Advertencia Attention Maximum humidity threshold Umbral de humedad m ximo Seuil d humidit maximum The device accessories and t...

Page 3: ...BewellConnect BW GL1 User Manual 022017v1 4 BW GL1 MyGluco EN...

Page 4: ...r blood glucose levels by yourself anywhere any time If you have other questions regarding this product please contact customer service INTENDED USE This system is intended for use outside the body in...

Page 5: ...before use Patients suffering from decompensated heart failure NYHA Class IV or peripheral arterial occlusive disease should also consult a healthcare professional before use this device The measureme...

Page 6: ...T 2 Setting the time format Press UP or DOWN to select the desired time format 12h or 24h Press REPEAT 3 Setting the time With the HOUR MINUTE flashing in sequence press UP or DOWN until the correct h...

Page 7: ...ill mix up the blood glucose test results with the control solution test results in memory 3 Apply control solution g Shake the control solution vial thoroughly before use Squeeze out the first drop a...

Page 8: ...sample k Gently apply the drop of blood to the absorbent hole of the test strip at a tilted angle Confirmation window should be completely filled if enough blood sample has been applied DO NOT remove...

Page 9: ...along with respec tive dates and times in its memory To enter the meter memory start with the meter switched off 8 1 REVIEWING TEST RESULTS 1 Press and release M will appear on the display Press M aga...

Page 10: ...in the memory As with all small batteries these batteries should be kept away from children If swallowed promptly seek medical assistance Batteries might leak chemicals if unused for a long time Remo...

Page 11: ...er service for assistance E F Appears when test strip is removed while counting down Review the instructions and repeat test with a new strip If the problem persists please contact customer service fo...

Page 12: ...e External output Bluetooth Auto electrode insertion detection Auto reaction time count down Auto switch off after 3 minutes without action Temperature Warning Operating Condition 50 F to 104 F 10 C t...

Page 13: ...r mejor su diabetes Gracias a su tama o compacto y f cil manejo puede usar el Sistema de monitoreo de la glucemia MyGluco BW GL1 para controlar sus niveles de glucosa usted mismo y en cualquier moment...

Page 14: ...rica Por favor p ngase en contacto con un profesional de la salud antes de utilizar el producto Los pacientes que sufren de insuficiencia card aca New York Heart Association NYHA clase IV o una enfer...

Page 15: ...2 Ajustar el formato de la hora Pulse Arriba UP o Abajo DOWN para seleccionar el formato deseado 12h o 24h Pulse Repetir REPEAT 3 Ajustar la hora Con la HORA MINUTOS parpadeando en secuencia pulse Arr...

Page 16: ...e el gluc metro muestre y 2 Pulse M para marcar esta prueba como una de soluci n de control Cuandosevisualiza CTL elgluc metronomemorizaelresultadodesupruebaen CTL SivuelveapulsarM CTL desapareceyesta...

Page 17: ...prueba De lo contrario puede sufrir dolores y producirse callosidades Consulte a un profesional de la salud antes de realizar una prueba en una zona alternativa Serecomiendadesecharlaprimeragotadesang...

Page 18: ...prueba puede representar un riesgo biol gi co Des chelas cuidadosamente respetando la normativa local 7 4 PRUEBA EN ZONAS ALTERNATIVAS reas de Prueba Sugeridas para la Mano Antebrazo Parte superior d...

Page 19: ...TOOTH Para enviar su s medici n es a su celular o tablet abra la aplicaci n MyGluco y abra la pantalla de medici n Active la funci n Bluetooth en su celular o tablet y tambi n en el gluc metro Hay dos...

Page 20: ...ayuda m dica inmediatamente Para mayor informaci n rem tase al folleto del paquete de tiras de prueba 10 5 INFORMACI N IMPORTANTE SOBRE LA SOLUCI N DE CONTROL Utilice nicamente nuestras soluciones de...

Page 21: ...cha de caducidad de la soluci n de control La soluci n de control est demasiado tibia o fr a Antes de realizar la prueba la soluci n de control y las tiras reactivas deben estar a temperatura ambiente...

Page 22: ...BewellConnect BW GL1 User Manual 022017v1 BewellConnect BW GL1 User Manual 022017v1 42 43 BW GL1 MyGluco FR...

Page 23: ...re taux de glyc mie peut vous aider ainsi que votre m decin mieux contr ler votre diab te Gr ce son format compact et son fonctionnement sim ple vous pourrez utiliser le lecteur de glyc mie MyGluco BW...

Page 24: ...v re et des pertes excessives d eau peuvent conduire des mesures inf rieures aux valeurs r elles Si vous pensez souffrir de d shydratation s v re consultez imm diatement un m decin L hyperglyc mie acc...

Page 25: ...piles CRAN 12 13 1 2 3 4 9 10 11 7 6 5 8 1 R sultat de l analyse de sang 2 Mode Solution de contr le CTL Test r alis avec la solution de contr le 3 Date 4 Heure 5 Symbole de l alarme 6 Symbole de pil...

Page 26: ...er d alarme appuyez sur le bouton de validation pour s lectionner OFF et passer cette tape Si vous voulez programmer une alarme appuyez sur le bouton de validation pour s lectionner On Lorsque les ind...

Page 27: ...ce r sultat avec la fourchette indiqu e sur le flacon de bandelettes Le r sultat devrait se situer dans cette plage Dans le cas contraire lisez une nouvelle fois les instructions et recommencez le tes...

Page 28: ...sang 4 D posez l chantillon k Placez d licatement la goutte de sang sur le trou absorbant de la bandelette de test en l inclinant Si une quantit suffisante de sang a t d pos e la fen tre de confirmati...

Page 29: ...ent d utiliser les autres sites de pr l vement UNIQUE MENT dans les cas suivants A l tat pr prandial ou de je ne plus de 2 heures apr s le dernier repas Deux heures ou davantage apr s avoir pris de l...

Page 30: ...alcalines AAA de 1 5 V SIGNAL DE PILES FAIBLES Le lecteur affichera l un des messages ci dessous pour vous avertir lorsque le niveau des piles deviendra faible 1 Le symbole appara t avec le message s...

Page 31: ...s Il est recommand d effectuer le test avec la solution de contr le une temp rature ambiante de 68 F 77 F 20 C 25 C Assurez vous que la solution de contr le le lecteur et les bandelettes se trouvent d...

Page 32: ...ne temp rature ambiante situ e entre 68 F et 77 F 20 C et 25 C avant de proc der aux tests Bandelette de test d fectueuse Recommencez le test avec une bande lette neuve Panne du lecteur Veuillez conta...

Page 33: ...BewellConnect BW GL1 User Manual 022017v1 BewellConnect BW GL1 User Manual 022017v1 64 65 WA R R A N T Y...

Page 34: ...tive appearance due to the display of the product for sale in showrooms retail outlets for demonstration purposes etc Normal use cleaning and replacement of parts with normal wear and tear are not cov...

Page 35: ...our une p riode d un 1 an lorsqu il sont utilis s dans des conditions normales conform ment la documentation du produit sous r serve des conditions et restrictions nonc es ci dessous La garantie du pr...

Page 36: ...tion Veuillez respecter les r glements et r gles locaux 02 2017 BW GL1 EN BewellConnect is a brand registered by Visiomed Group SA The constructor keeps the right to modify the photographs and charact...