BC610 Installation and User manual
Door operation on change of toggle enable
The default setting is that if the door is unlocked when a
security level changes, the door will be locked immediately.
This is setting 0 of this function.
This function can be changed so that the door remains
unlocked when a security level changes. This is setting 1 of
the function.
To lock the door a valid transaction must be performed as
required during the new security level. (e.g.
Card + PIN
)
1
Set the card reader to programming mode.
2
Press A96.
"!"
3
Press 1 for setting 1.
Press 0 for setting 0 (this is the default setting).
4