Change the Door Opening time
The opening time determines for how long the lock should
remain open following a correct entrance. The default is 7
seconds. This is how to change the opening time, if required.
1
Set the card reader to programming mode.
2
Press A28.
"""
3
Enter the desired opening time (between 01 and 99
seconds).
4
Press B to leave programming mode.
Buzzer on/off
The default is that the buzzer is activated. If you do not want
the buzzer to beep on key presses or door opening, it can be
turned off. Note that even when the buzzer is off for normal
operation, it will continue to sound during programming.
1
Set the card reader to programming mode.
2
Press A65.
""!
3
Press 0.
4
Press B to leave programming mode.