TROUBLESHOOTING TIPS
No Power
If your proofer fails to start when the power is applied via power switch:
1. Check to see if the unit is properly connected to correct power source as specified on the serial
number label.
2. Check to see that your power source (wall receptacle) has power - inspect circuit breaker.
3. Disconnect power cord and visually inspect for any damage.
4. Contact the Bevles Technical Service Department tor assistance.
Excessive Humidity
If your proofer is producing excessive humidity:
1. Check the setting on the humidity control knob on the control panel, to see if it is set where
you normally operate at.
2. Check the base of the cabinet to see if the excess humidity is draining through the drain hole
in the center of the base.
3. Contact the BevLes Technical Service Department for assistance.
No Humidity
If your proofer is producing no humidity, or considerably less than normally achieved:
1. Inspect water level in the water pan.
2. Check the setting on the humidity control knob on the control panel, to see if it is set where
you normally operate at.
3. Check to see if the cabinet door(s) are closed.
4. Make certain that the humidity-heating module's one inch air flow opening (at rear of module) is
behind the cabinet back vent that hangs on the rear wall of the cabinet.
5. Make certain that the polycarbonate water pan cover is correctly positioned over the entire
water pan and the louvers located in front of the water pan.
6. Verify that the fan blower is operating.
7. Contact the BevLes Technical Service Department for assistance.
Excessive Heat
If your proofer temperature is higher than normal:
1. Check the setting on the temperature control to see if it is set where you normally operate at.
2. Check the ambient room temperature to see if it is greater than your desired proofing
temperature.
3. Contact the BevLes Technical Service Department for assistance.
No Heat
If your proofer is producing no heat, or considerably less than you normally achieve:
1. Check the setting on the temperature control to see if it is set where you normally operate at.
2. Check to see if the cabinet door(s) is completely closed.
3. Make certain that the humidity-heating module's one inch air-flow opening (at rear of module) is
behind the cabinet back vent that hangs on the rear wall on the cabinet.
4. Verify that the fan blower is operating.
5. Contact the BevLes Technical Service Department for assistance.