TROUBLESHOOTING TIPS

 

No Power

 

If your proofer fails to start when the power is applied via power switch: 

1.  Check to see if the unit is properly connected to correct power source as specified on the serial 

number label. 

2.  Check  to see that  your power  source  (wall  receptacle)  has  power  -  inspect  circuit  breaker. 
3.  Disconnect power cord and visually inspect for any damage. 
4.  Contact the Bevles Technical Service Department tor assistance. 

 

Excessive Humidity

 

If your proofer is producing excessive humidity: 

 

1.  Check the setting on the humidity control knob on the control panel, to see if it is set where 

you normally operate at. 

2.  Check the base of the cabinet to see if the excess humidity is draining through the drain hole 

in the center of the base. 

3.  Contact the BevLes Technical Service Department for assistance. 

 

No Humidity

 

If your proofer is producing no humidity, or considerably less than normally achieved: 

1.  Inspect water level in the water pan. 
2.  Check the setting on the humidity control knob on the control panel, to see if it is set where 

you normally operate at. 

3.  Check to see if the cabinet door(s) are closed. 
4.  Make certain that the humidity-heating module's one inch air flow opening (at rear of module) is 

behind the cabinet back vent that hangs on the rear wall of the cabinet. 

5.  Make certain that the polycarbonate water pan cover is correctly positioned over the entire 

water pan and the louvers located in front of the water pan. 

6.  Verify that the fan blower is operating. 
7.  Contact the BevLes Technical Service Department for assistance. 

 

Excessive Heat

 

If your proofer temperature is higher than normal: 

1.  Check the setting on the temperature control  to see if it is set where you normally operate at. 
2.   Check the ambient room temperature to see if it is greater than your desired proofing                                                 

temperature. 

3.   Contact the BevLes Technical Service Department for assistance. 

 

No Heat

 

If your proofer is producing no heat, or considerably less than you normally achieve: 

 

1.  Check the setting on the temperature control to see if it is set where you normally operate at. 
2.  Check to see if the cabinet door(s) is completely closed. 
3.  Make certain that the humidity-heating module's one inch air-flow opening (at rear of module) is 

behind the cabinet back vent that hangs on the rear wall on the cabinet. 

4.  Verify that the fan blower is operating. 
5.  Contact the BevLes Technical Service Department for assistance. 

 

 

 

 

 

 

Summary of Contents for Cinnabon PICA70-32-AED

Page 1: ...according to theinstructions in this manual and standard commercial kitchenpractices Toll Free 844 265 0250 Fax 800 548 9392 Website www BevLes com E mail sales BevLes com P N 780086 3 06 BevLes 1525...

Page 2: ...Replacement 7 Wiring Diagram 120v 8 Wiring Diagram 208 230v 9 Parts List 10 Notes 11 Warranty 12 SAFETY PRECAUTIONS Before installing and operating this equipment be sure everyone involved in its ope...

Page 3: ...on must comply with the Canadian Electrical Code CSAC22 2 as applicable NOTICE Local codes regarding installation vary greatly from one area to another The National Fire Protection Association Inc sta...

Page 4: ...the serial number label located on the left side of the unit 6 Release all wheel brakes SETTING UP 1 Remove all protective film from interior and exterior surfaces on cabinet and doors 2 Place the ca...

Page 5: ...any condensation 8 Verifythat the door s is closed and latched 9 Allow approximately 30 45 minutes for the cabinet to achieve the necessary temperature and humidity that you desire 10 Thecabinet is n...

Page 6: ...d water Clean polycarbonate water pan cover and door s with soft sponge soap and water NEVER USE HARSH CLEANING SUBSTANCES OR ABRASIVES TO CLEAN POLYCARBONATE SURFACES ORTHE CAST ALUMINUMWATERPAN 7 Re...

Page 7: ...et door s are closed 4 Make certain that the humidity heating module s one inch air flow opening at rear of module is behind the cabinet back vent that hangs on therearwall of the cabinet 5 Make certa...

Page 8: ...and 7 5 Remove screws 3 and stainless steel drip edge 6 Turn module over and remove screws from the bottom of the module 7 screws each side There will be 4 nylon caps and spacers save and reuse 7 Remo...

Page 9: ...8 Amp rating 120v Models 13 amps...

Page 10: ...9 Amp rating 208 230v Models 7 5 6 8 amps...

Page 11: ...r 1 760055 Replacment Door Glass Polycarbonate Clear 3 740223 Bracket Mounting Sensor 1 782092 Knob Infinite Switch Black 1 740348 Upright 50 75 Long 1 1 2 Spacing 4 781295 Drain Brass 1 742745 Drain...

Page 12: ...11 Notes...

Page 13: ...void in its entirety if any abuse of misuse of alteration modification of or improper maintenance of original product occurs If at any time a claim is reported to Bevles and the purchaser is delinque...

Page 14: ...13 Toll Free 844 265 0250 Fax 800 548 9392 Website www BevLes com E mail sales BevLes com BevLes 1525 East Lake Rd Erie Pa 16511...

Reviews: