5
process has started, the proofer door(s) should not be opened until proofing has been completed.
The 18" x 13" sheet pan (not provided with proofer) that serves as a drip pan under the cabinet base
should be checked, and if necessary, emptied at the end of each day.
The cabinet should be cleaned whenever necessary. It should be thoroughly cleaned at least once a week.
Note:
It is recommended that humidity be kept at the minimum level that is practical for your operation.
Excessive humidity with condensation on the walls and/or base of the cabinet is not considered desirable.
SAFETY AND HEALTH
BevLes Proofing Cabinets meet all cUL and NSF requirements. Always operate this proofer in
accordance with the operating instructions found in this manual. Never remove the humidity-heating
module without first disconnecting (unplugging) the unit from its power source. The cabinet is designed
and built for easy cleaning. It should be cleaned frequently as described in the maintenance section.
MAINTENANCE
Cleaning: This cabinet was designed and built for maximum sanitation. It is not self cleaning, so it should
be cleaned frequently with soap and water.
1. NEVER USE STEEL WOOL OR CAUSTIC CLEANING COMPOUNDS.
2. Make sure that the unit is turned OFF and
disconnected
from the electrical service.
3. Remove the polycarbonate water pan cover and side covers from the humidity-heating
module.
4. Remove the pan supports and vertical uprights.
5. Remove the vent from the rear wall.
6. Clean inside of cabinet with soap and water. Clean polycarbonate water pan cover and
door(s) with soft sponge, soap and water.
NEVER USE HARSH CLEANING SUBSTANCES OR ABRASIVES TO CLEAN
POLYCARBONATE SURFACES, OR THE CAST ALUMINUM WATER PAN.
7. Remove and clean the 18" x 13" drip pan (not provided with proofer) from under the cabinet
base.
If necessary, the humidity-heating module can be removed by, first disconnecting the external drain and
removing the coupling,(fig.1). Then removing the two (2) black knobs (one located at each side on the
module on the exterior of the cabinet). The module can be pulled out of the cabinet for additional cleaning.
We suggest that you clean the water pan at least once a month with a solution of white vinegar and hot
water. Allow white vinegar to remain in water pan overnight. Then use a soft cloth to wipe away any mineral
buildup.
Important:
When placing the humidity heating module back into the cabinet make certain that the module is
pushed tightly against the cabinet and secured with the two (2) black knobs. Check to see that the one
inch air flow opening at the rear of the humidity-heating module is behind the back vent that hangs on the
rear wall of the cabinet. This is necessary to maintain uniform temperature and humidity distribution
throughout the cabinet.
IF REPLACEMENT PARTS ARE EVER REQUIRED, ONLY USE PARTS THAT HAVE BEEN
APPROVED BY BEVLES COMPANY, INC.
Should you require assistance, or service contact the BevLes service line at (844)265-0250 When you
phone please have the model number and serial number of the proofer. This will assist our service
technicians in providing you immediate assistance. You may want to briefly review the Troubleshooting
Tips before you contact our factory.
Summary of Contents for Cinnabon PICA70-32-AED
Page 9: ...8 Amp rating 120v Models 13 amps...
Page 10: ...9 Amp rating 208 230v Models 7 5 6 8 amps...
Page 12: ...11 Notes...