8. Storage
If you do not plan to use the device for 2 to 3 days, we recommend that you unplug it and store it thoroughly
empty, clean and dry in the original packing in a dry environment. Ensure that no objects are placed on top
of the device.
9. What if there are problems?
Problem
Cause
Solution
The device is not working. The device is not connected to
mains power supply.
Connect the mains plug and switch on
the device.
The device has switched itself off
due to safety reasons.
Clean and refill the device before next
use. Then switch it on again.
The device automatically
stops when dehumidifying.
The water tank is full.
Empty the water tank, then start up the
device again.
The water tank was not put back
in correctly.
Put the water tank in the correct posi-
tion.
The air filter is blocked.
Clean the air filter.
The ambient temperature is below
0°C.
The ambient temperature must be
above 0°C.
The ambient temperature is above
40°C.
The ambient temperature must be
below 40°C.
The device is working but
is not reducing the relative
air humidity enough.
The room is too big.
The device is only suitable for a room
size of up to 30 m².
The air filter is blocked.
Clean the air filter.
The air intake/air outlet is blocked. Ensure that the air intake/outlet is not
blocked.
There too much exchange of air in
the room.
Close the windows and doors.
10. Replacement parts and wearing parts
Replacement parts and wearing parts are available from the corresponding service address (according to
the service address list). Please state the corresponding order number.
Designation
Item number and/or order number
Plastic cover with filter
163.833
Water tank
163.831
Condensate hose
163.647
11. Technical specifications LE 30
Model
LE 30
Mains voltage / power
See type plate on the device
Protection class
I /
IP protection class
IPX0
Dimensions (L x W x H)
290 x 190 x 478 mm
Weight when empty
approx. 9.5 kg
Recommended room size
20-30m²
Maximum tank capacity
approx. 1.8 litres
Dehumidifying capacity
approx. 10 litres/24 h (30°C room temperature / 80% relative humidity)
Cooling agent / quantity
R 134a, 92 g
Permissible operating temperature
5°C – 35°C
Subject t
o err
ors and changes
Summary of Contents for LE 30
Page 61: ...61 Beurer LE 30 8 30...
Page 63: ...63 LE 30 50 20 30 2 LE 30 LE 30...
Page 64: ...64 3 250 T 10 A L...
Page 65: ...65 35 C 5 C WEEE Waste Electrical and Electronic Equipment 4 1 5 2 6 3 7 4 1 2 3 4 5 6 7...
Page 67: ...67 6 2 50 SETTING SETTING 40 50 60 6 3 2H 4H 6H 6 4 1 C 30 10 6 5 10 1 ON OFF 2 3 4 6 6 0 C...
Page 68: ...68 40 C ON OFF 6 7 1 2 3 LE 30 4 5 6 7...