17
8. Disposal
For environmental reasons, do not dispose of the device in the household waste at the end of its useful
life. Dispose of the unit at a suitable local collection or recycling point. Dispose of the device in accord-
ance with EC Directive – WEEE (Waste Electrical and Electronic Equipment). If you have any questions,
please contact the local authorities responsible for waste disposal.
The empty, completely flat batteries must be disposed of through specially designated collection boxes, recycling
points or electronics retailers. You are legally required to dispose of the batteries.
The codes below are printed on batteries containing harmful substances:
Pb = Battery contains lead,
Cd = Battery contains cadmium,
Hg = Battery contains mercury.
9. Incorrect measurement
If the scale detects an error during weighing, “
2
” or “
” appears in the display.
If you step onto the scale before “
0.0
” appears in the display, the scale will not operate properly.
Possible causes of errors
Remedy
– The maximum load-bearing capacity of 150 kg was
exceeded.
– Only weigh the maximum permissible weight.
– Not standing still.
– Stand as still as possible.
– The electrical resistance between the electrodes
and the soles of your feed is too high (e.g. with
heavily callused skin).
– Repeat weighing barefoot.
– Slightly moisten the soles of your feet if necessary. Re-
move the calluses on the soles of your feet if necessary.
– Your body fat lies outside the measurable range
(less than 5% or greater than 80%).
– Repeat weighing barefoot.
– Slightly moisten the soles of your feet if necessary.
– The proportion of water is outside the measurable
range (less than 43% or greater than 75%).
– Please repeat the measurement barefoot.
– Dampen the soles of your feet slightly.
10. Technical specifications
Model:
BG 13
Dimensions:
30 x 30 x 1.8 cm
Weight:
1549 g
Measurement range:
5-150 kg
Scale interval d:
The display can be read in increments of 0.1 kg.
Repetition accuracy:
The measuring tolerance for repeated measurements is +/- 0.4 kg (several
measurements in direct succession on the same scale with position of scale and
person the same as far as possible).
Absolute precision:
In comparison with a calibrated weight, the measured value is +/- (1% + 0.1kg),
e.g. at 40 kg this corresponds to +/- 0.5 kg; at 100 kg this corresponds to +/- 1.1
kg.
Subject to technical changes.
11. Warranty
Further information on the warranty and warranty conditions can be found in the warranty leaflet supplied.
Subject t
o err
ors and changes