Bettis P/N 126858
Revision "F"
Page 14 of 15
5.3.25 Retain the control valve (20-190) to the manifold by install screws through the control valve
body and screwing into the manifold (20-10). Tighten control valve screws to tight plus 1/4
turn.
5.3.26 Install the position label (20-230) onto the control valve. NOTE: The label for spring return
actuators will be mounted with the two-position (“AUTO” or “MANUAL”) side of the label
facing outward. If the actuator is a double acting model then the three-position (“MANUAL
CW”, “AUTO” and “MANUAL CCW”) side of the label will be facing outward.
5.3.27 Retain the position label with one type “AB” self tap hex head screw (20-240).
5.3.28 Install the control pointer (20-200) onto the control valve (20-190).
5.3.29 Install the control knob (20-320) onto the control valve (20-190).
5.3.30 Retain the control knob (20-320) on the control valve (20-190) with one socket cap screw
(20-180) & lockwasher (20-185)
5.3.31 Install the manifold (20-10) onto the mounting bracket (30-90) using four countersunk flat
socket screws to retain the manifold to the mounting bracket.
5.3.32 Install the M11 package/mounting bracket (30-90) onto the actuator housing mounting pad
using four socket cap screws.
NOTE: If the M11 pump is equipped with Auto Reset then do steps 5.3.33 and 54.3.34 or if non
Auto Reset M11 skip steps 5.3.33 and 5.3.34.
5.3.33 Install the male swivel elbow to the Bimba Cylinder (40-90).
5.3.34 Install the bracket (40-50) on the reservoir side of the manifold (20-10) and retaining the
bracket with two socket cap screws (40-10).
5.3.35 Reinstall any piping that was removed from the M11 package.