7
3. BATTERY INSTALLATION
The machine will be supplied with a battery charger and either two 12 V Wet or
AGM batteries. The batteries must be housed in the battery tray in the battery
compartment beneath the recovery tank.
To insert the batteries you must:
A. Lower the squeegee and base.
B. Open the rear latch that secures the tank (2).
C. Rotate the recovery tank as far as it will go, using the side handle (3).
WARNING: To avoid acid spillage you can use sealed batteries.
WARNING: Perform one battery charging cycle before using the
machine.
4. TYPE OF BATTERY
To power the machine you can use:
• Wet
batteries
• AGM
batteries
• Gel
batteries
OTHER TYPES MUST NOT BE USED.
The maximum dimensions and weight are:
Width 6.8 in. (172 mm)
Length 14.2 in. (360 mm)
Height 11.2 in. (285 mm)
Weight 97 lb. (44 kg)
WARNING: Your charger must be set according to the type of bat-
tery you install. Call BETCO customer service to ensure correct
charger setting after replacement batteries are installed.
• The batteries must be handled using lifting and transportation means suitable
for the weight and dimensions.
• They must be lifted by the handles on the upper part.
• They must be connected together in series, to obtain an overall voltage of 24
V on the lugs.
• The electrical connection operations must be carried out by certifi ed trained
personnel.