- 4 -
OPERATION
For quiet operation and best capture of smoke, steam and other cooking impu-
rities, always operate this unit with the slide-out visor fully open.
Controls
The hood is operated using the (5) push buttons located on the slide-out visor.
The
Light O
ff
/On
switch turns the lights on to low intensity and turns them o
ff
.
The
Light Dimmer
switch alternates light intensity from low to high.
The
Blower O
ff
/Speed
switch turns the blower o
ff
and changes blower speed to
four di
ff
erent speed settings: high, medium-high, medium-low and low speed.
Depress and hold the button for 2 seconds to turn the blower o
ff
.
The
Blower On/Speed
switch turns the blower on to four di
ff
erent speed settings:
Low, medium-low, medium-high and high speed. The visor must be open for the
blower to be operational.
The
LED Display
:
Indicates blower speed selection from 1 (lowspeed) to 4 (high speed).
Flashes the blower speed when the 10-minutes delay o
ff
has been activated.
After 30 hours of operation, the center segment of the display blinks and remains
lit, indicating that
fi
lters need to be cleaned.
The
Time Delay
switch activates a delay o
ff
feature. When pushed, the blower will
continue to operate at the current speed setting for 10-minutes before automatically
turning itself o
ff
.
The
Filter Alarm Reset
switch is used to reset the 30-hour
fi
lter timer. After
fi
lters
are cleaned or replaced, press this switch once to reset the
fi
lter clean alarm.
HEAT SENTRY™
Your hood is equipped with a HEAT SENTRY™ thermostat. This thermostat is a
device that will turn on or speed up the blower if it senses excessive heat above
the cooking surface.
1) If blower is OFF - it turns blower ON to HIGH speed.
2) If blower is ON at a lower speed setting - it turns blower up to HIGH speed.
When the temperature level drops to normal, the blower will return to its original
setting.
WARNING : The HEAT SENTRY thermostat can start the blower even if
the hood is turned OFF. When this occurs, it is impossible to turn the blower
OFF with its switch. If you must stop the blower, do it from the main electrical
panel.
Summary of Contents for U102I
Page 13: ... 13 SERVICE PARTS MODEL U102I ...
Page 27: ... 27 PIECES DE RECHANGE MODÈLE U102I ...
Page 41: ... 41 PIEZAS DE REPUESTO MODELO U102I ...
Page 43: ... 43 ...
Page 44: ... 44 04308928 99043479E ...