Besam AAE977 Installation Manual Download Page 8

Ultraview US23-0640-09 

 

 

 

 

 

07-30-09 

 

 

 

      V4

© Copyright 2009 Besam US Inc.  May not be reprinted without permission               

 

                        8

Remote Control

The remote control provides ease of programming for the Ultraview.  Make sure 

the batteries in the remote control are charged - replace as necessary.

Open the battery compartment at the back of the remote control. 

Insert 2 AAA batteries.

 

1:normal

(LED in normal mode)

2:door permanently open

(red LED ON)

3:door permanently closed

(red LED OFF)

Door Control

0(min)->9(max) 

default=7

Sensitivity

Microwave

Detection Mode

1:bidirectional mode

2:unidirectional mode

3:unidirectional mode with MTF

Setup

launch an assisted setup

restore factory settings

When restoring factory defaults(Magic 

Wand+9), the sensor will self-launch a 

setup, but will not change the designation 

of P1 and P2

Automatic 

Learn Time

0: 30 seconds

1: 1 minute

2: 2 minutes

3: 5 minutes

4: 10 minutes

5: 20 minutes

6: 60 minutes

9:Infinity - no learn

Re-entry Zone

1(min sensitivity)->9(max sensitivity)

Default=3 

0 = off

Unlock

Check values

Lock

SPECIAL NOTE: In the event you believe the frequency needs changed 

for your application please contact the Besam factory.

Summary of Contents for AAE977

Page 1: ...0 09 07 30 09 V4 Copyright 2009 Besam US Inc May not be reprinted without permission 1 Complies with ANSI BHMA A156 10 Standard for Power Operated Pedestrian Doors UL325 Listed Besam UltraView Install...

Page 2: ...r detection performance SPECIAL NOTE The Ultraivew works differently than the BEA Wizard When making changes to the Ultraview reference the Ultraview users guide If you inadvertently make changes base...

Page 3: ...roduct conformity R TTE 1999 5 EC EMC 89 336 EEC FCC Interface Factory Installed Technology Microwave and microprocessor Transmitter frequency 24 125 GHz Transmitter radiated power 20 dBm EIRP Transmi...

Page 4: ...connector on the Ultraview Interface Board Ultraview US23 0640 09 07 30 09 V4 Copyright 2009 Besam US Inc May not be reprinted without permission 4 MOUNTING SCREWS INFRARED LENS SHROUD SENSOR COVER U...

Page 5: ...the push button is released Then repeat step 2 5 Mechanically adjust the presence field of each sensor for the installation a Launch a setup of the system by momentarily pressing and releasing the rig...

Page 6: ...LENS FACTORY DEFAULT 6 6 W X13 75 D CHANGE PRESENCE LENS IF NEEDED REMOVE BEZEL OPTIONAL NARROW ANGLE ANTENNA ADJUST ANGLE BY TILTING MICROWAVE CELL 7 0 height 13 W X 6 6 D 6 6 W X 8 2 D Wide Narrow...

Page 7: ...t off main power to the Unislide wait 5 seconds 6 Re apply power 7 Unlock P1 press unlock then 1 8 Press magic wand on the remote control 9 Press 0 this will launch a set up Keep traffic away from the...

Page 8: ...rol 0 min 9 max default 7 Sensitivity Microwave Detection Mode 1 bidirectional mode 2 unidirectional mode 3 unidirectional mode with MTF Setup launch an assisted setup restore factory settings When re...

Page 9: ...he door will not re cycle open at this time it will continue to close because the motion output is going to the Outer Impulse at the control box which has been ignored due to the 1 way traffic selecti...

Page 10: ...eter being altered 1 flash means value 1 The right button enables selection of the parameter number being altered 1 for each press The left button enables alteration of the value 1 for each press EXAM...

Page 11: ...resence If LED s are illuminat ing make sensor adjustments as necessary to eliminate unwanted detection Check angle and sensitivity for presence and motion see pg6 2 Check for moving objects in the pa...

Page 12: ...pressing the reset button next to the 5 position switch 3 Select correct sensor with P1 1 Reset system to neutral 2 Power Off On by pressing the reset button next to the 5 position switch 3 Select co...

Page 13: ...ows the User to toggle between STD and AUX The STD position is the default position The AUX position is selected for applications that require initial activation by the Knowing Act device only Thus wh...

Page 14: ...cover position to the 1 way traffic mode The AUX input will not be acknowledged when placed in the STD position KNOWING ACT TO PUSH PLATES DRY CONTACT ONLY DIP SWITCH P1 P2 TO BREAKOUT SWITCHES 1 Wir...

Page 15: ...activation regardless of door position 3 Setting the rotary switch to the OFF position will disable all inputs once the door is fully closed c Part Time 1 Way Security Day Night Mode Set STD AUX swit...

Page 16: ...bottom guide assembly for proper adjustment and excessive wear 13 Check door closing speed and closing force 14 Check closing latch location 15 Check that door hold open time is 1 5 seconds or longer...

Reviews: