16
82.526 - HERMES
4.4 SPRAYING FUNCTIONS: POSITIONS 1-10
NOTE:
The rinsing functions allow partial rinsing if there is no change of products but not a complete
rinsing of the circuit (for that, 4.5).
FUNCTIONS
Position of the
index on the
wheel
Position of the valves
State of the
sections
Power
take-off
A
B
C
D
Priming / Filling the main tank from
outside
Closed
540 rpm
Mixing the product via the hopper using
the rinsing tank
Closed
540 rpm
Filling the main tank from outside
Closed
540 rpm
Mixing the product via the hopper using
the main tank
Closed
540 rpm
Spraying
Without agitation
Open
540 rpm
With 50% agitation
Between and
With 100 % agitation
Rinsing the boom using the rinsing tank
(clean water)
Open
300 rpm
Rinsing the main tank using the rinsing
tank (clean water)
Closed
300 rpm
Rinsing the main tank using the main tank
Closed
300 rpm
External washing option
Closed
300 rpm
Isolating the circuit (cleaning the filters)
Closed
0 rpm
WARNING
All operations on valves must be done with the power take-off stationary.
16
B
D
C
A
Summary of Contents for HERMES 1000
Page 22: ...22 82 526 HERMES 7 SPRAYING CIRCUIT...