82.526 - HERMES
13
3.4 RINSING THE EQUIPMENT BEFORE USING IT FOR THE FIRST TIME
WARNING:
Before using your sprayer with phytosanitary products for the first time (herbicide,
insecticide or other), the equipment must be flushed completely.
• Remove the nozzles if they are fitted.
• Unscrew the end caps from the pipes.
• Fill the tank to 1/5 with water.
• Spray ( 4.4, page 16).
• Remove and clean the filters.
• Replace the end caps on the pipes.
• Fit the nozzles.
NOTE:
This will eliminate any foreign particles
that might be in the spraying circuit and
which could otherwise block nozzle
orifices.
3.5 RECOMMENDATIONS FOR USE
When starting up:
• Start the tractor engine.
• Power up the controls.
• Engage the power take-off.
Always check:
• Run the flow from the nozzles at a pressure of 3 bars for 1 minute before starting the spraying session,
• If the flow is 10% higher than the initial value, the nozzles should be replaced.
WARNING:
All operations on valves must be done with the power take-off stationary.