5.3 CLOGGED NOZZLES
Clean with a brush and rinse clogged nozzles with water.
For this, use the brush/wrench (BERTHOUD reference
779.354).
WARNING:
Never blow into a nozzle.
5.4 EXTERNAL WASHING OPTION
• Unclip the brush..
• Attach it to the quick connector on the unwinder.
• Set the index on the wheel to function
( 4.4, page 16) and then proceed with cleaning.
• When washing is complete, put the brush back
in its place.
The use of a detergent is recommended to facilitate
cleaning:
- All Clean (5 l) BERTHOUD reference 788.796.
- All Clean Extra NF (5 l) BERTHOUD reference
788.792.
i
WARNING:
We recommend that you wash the
outside of the sprayer, once rinsing is
complete
( 4.5, page 17) to avoid
contaminating the outside again.
5.5 PROTECTION AGAINST OXIDISING AGENTS.
• Prior to treatments using liquid fertiliser, it is desirable to protect the equipment and boom completely
by spraying with an oily product, so as to prevent any attack by rust or deterioration of the paintwork.
• Rinsing with a pressure jet after treatment will remove any trace of dust and the oily product
5.6 CHECK BEFORE THE SPRAYING SEASON STARTS
Filters:
Make sure that the suction and delivery filters are clean and in good condition.
Pipes:
Look for any leaks. Check for kinks in the pipes.
Seals and connectors:
Check that connection nuts are tightened and change seals if necessary.
Pump, reduction gear, angle transmission:
Check the oil levels.
Nozzles:
Change the nozzles once per year or if their flow rate is 10% to 15% greater than their initial flow rate.
For this use FLOW TEST, BERTHOUD reference 765.241 or FLOW COMPARATOR, BERTHOUD reference
778.887.
Tank:
Check that there is no foreign matter in the tank.