7
- The power cord must be positioned so that an over temperature of 75 K will not be
reached at any point.
- Do not use reductions, adapters or splitters since they might cause false contacts
and lead to dangerous overheating.
When the connection is made directly to the electric network:
- Use a device that ensures disconnection from the mains in which the contacts are
opened to a distance that permits complete disconnection according to the
conditions for over-voltage category III.
- Remember that the ground wire must not be interrupted by the circuit-breaker.
- As an alternative, the electric connection can also be protected by a high-sensitivity
residual current circuit-breaker.
- It is highly recommended to attach the special green-yellow ground wire to an
efficient ground system.
WARNING: If the power cord is replaced, the ground wire (yellow-green) connected
to the terminal, should be longer than the other wires by about 2 cm.
WARNING: The power cord should be replaced only by qualified personnel.
Types of power cords The appliance is equipped with a terminal for the electric connection placed behind,
which is accessible by removing the posterior casing.
The cable of alimentation can be :
Operation at 220-240V~ : use a H05BB-F three-wire cable (cable 3x2,5 mm²)
Operation at 380-415V2N~ : use a H05RR-F o H07RN-F four-wire cable (cable 4x1,5 mm²)
Operation at 380-415V3N~ : use a H05RR-F o H07RN-F five-wire cable (cable 5x1,5 mm²)
The power supply cable is suitable for appliance operating on 220-240 V~
ATTENTION: The appliance conforms with the regulations of directives
2009/142/CE (Gas Directive) regarding gas appliances for domestic use and
the like, 2006/95/CE (Low Voltage Directive) regarding electrical safety and
2004/108/CE, (EMC Directive) regarding electromagnetic compatibility.
Ensure that the electricity supply is switched off before making the connection. This
appliance must be earthed.
Connection to the electricity supply must be made through the flex cable that is
already attached to the rear of the cooker. The end of the cable is tucked into the
cooker storage area.
Connection to the supply must be made through fixed wiring. It cannot be connected
to a normal domestic power socket. A double pole switched cooker box should be
used with contact separation of at least 3mm.
Turn on each hob zone to check that all elements are functioning correctly. Remove
all packaging and combustible items from the oven. Turn on the oven selector switch
and thermostat knob to check that the oven is functional on all modes.
Adaptation to different
Before performing any maintenance operation, disconnect the appliance from
types of gas
the gas supply and electricity network.
Replacing the gas nozzles to operate with another type of gas:
Follow the instructions below to change the burner nozzles on the work
surface:
-
Isolate the appliance from the electric outlet to avoid any type of electric contact.
-
Remove the grids from the work surface.
-
Remove the burners.
-
Unscrew the nozzles using a 7 mm spanner, and replace them (Fig.4) with those
needed for the new type of gas
accordingly
.
Summary of Contents for her series