8
2
e
g
a
P
Maintenance & Trouble Shooting
-
Maintenance
For best performance, the certain minimal maintenance procedures should be performed before each
heating season:
•
A service agency qualified to adjust and repair infrared heaters should be engaged for service
other than routine maintenance.
•
Before performing any services or maintenance, shut off gas and electrical supply to heater.
•
Keep the appliance area clear and free from combustible materials, gasoline and other
flammable vapours and liquids.
•
Do not obstruct the flow of combustion and ventilation air.
•
Check condition of burner. Remove any foreign objects or debris from burner.
•
Inspect the igniter. Replace igniter if there is excessive wear or erosion, breakage or other
defects.
•
The reflector sections may be cleaned by wiping with a damp cloth.
•
Annually verify hose gas supply in heater post and all connections for gas leaks.
-
Trouble Shooting
No Gas Supply at Burner
•
Ensure manual shut off valve is in proper position
•
Ensure there is pressure and flow at inlet to gas valve.
•
Ensure gas valve gets 24v power from control module during ON cycle.
No Spark
•
Ensure control module has 24VAC supply
•
Ensure spark electrode assembly is grounded and there are no cracks in ceramic insulator.
Flame Lights but Will Not Stay Lit
•
Ensure there is no overpowering wind.
•
Ensure sense electrode is not corroded, is not grounded or has a cracked insulator. Electrode
position is radially across face of burner.
March, 2013
BERNER PATIO+ Luminous