background image

6

3

2

1

4

5

GRILLE
2501-0253-VAR

BACK PANEL
2701-0765-VAR

FRONT COVER
1402-0316-VAR

HEATING
ELEMENT

WIREWAY COVER
6405-0053-VAR

OVERLOAD
PROTECTOR
4520-0007-VAR

POWER RELAY
(OPTIONAL)

TRANSFORMER
RELAY
(OPTIONAL)

ELEMENT BUSHING
1213-2000-001

DISCONNECT
SWITCH
(OPTIONAL)

THERMOSTAT
(OPTIONAL)

6

3

2

1

4

5

GRILLE
2501-0254-VAR

BACK PANEL
2701-0766-VAR

FRONT COVER
1402-0315-VAR

HEATING
ELEMENT

WIREWAY COVER
6405-0053-VAR

OVERLOAD
PROTECTOR
4520-0007-VAR

POWER RELAY
(OPTIONAL)

TRANSFORMER
RELAY
(OPTIONAL)

ELEMENT BUSHING
1213-2000-001

DISCONNECT
SWITCH
(OPTIONAL)

THERMOSTAT
(OPTIONAL)

Heating Element (Part No. Prefix 1802-2001)

Description

Heater Length

28”

3’

4’

5’

6’

8’

10’

125W/Ft.

120V

085

087

089

091

093

-

-

per

208V

086

088

090

092

094

095

096

Element

240V

048

054

060

066

072

077

081

277V

049

055

061

067

073

078

082

188 W/Ft.

120V

005

011

017

023

029

-

-

per

208V

002

008

014

020

026

032

036

Element

240V

001

007

013

019

025

031

035

277V

000

006

012

018

024

030

034

250W/Ft.

120V

004

010

016

022

028

-

-

per

208V

003

009

015

021

027

033

037

Element

240V

002

008

014

020

026

032

036

277V

001

007

013

019

025

031

035

Built-In Controls (Optional)

Description

Part Number

CPLAM

CPLAS

Disconnect Switch

5216-0125-000

5216-0124-000

Transformer

120 Volt

R13700002B001

410043001

Relay

208 Volt

R13700002B002

410043002

240 Volt

R13700002B003

410043003

277 Volt

R13700002B004

410043004

Power

24 Volt

5018-2006-000

5018-2006-000

Relay

120 Volt

5018-2006-001

5018-2006-001

208/240 Volt

5018-2006-002

5018-2006-002

277 Volt

5018-2006-003

5018-2006-003

Thermostat

1 Pole

5813-0024-000

5813-0024-000

2 Pole

5813-0023-000

5813-0023-000

LIMITED WARRANTY

All  products  manufactured  by  Marley  Engineered  Products  are  warranted  against  defects  in  workmanship  and  materials  for  one  year  from  date  of  installation,  except 
heating elements which are warranted against defects in workmanship and materials for five years from date of installation. This warranty does not apply to damage from
accident,  misuse,  or  alteration;  nor  where  the  connected  voltage  is  more  than  5%  above  the  nameplate  voltage;  nor  to  equipment  improperly  installed  or  wired  or 
maintained in violation of the product’s installation instructions. All claims for warranty work must be accompanied by proof of the date of installation.

The customer shall be responsible for all costs incurred in the removal or reinstallation of products, including labor costs, and shipping costs incurred to return products
to Marley Engineered Products Service Center. Within the limitations  of this warranty, inoperative units should be returned to the nearest Marley authorized service cen-
ter or the Marley Engineered Products Service Center, and we will repair or replace, at our option, at no charge to you with return freight paid by Marley. It is agreed that
such repair or replacement is the exclusive remedy available from Marley Engineered Products.

THE ABOVE WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED, AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEED THE AFORESAID EXPRESSED WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED FROM
THIS  AGREEMENT.  MARLEY  ENGINEERED  PRODUCTS SHALL  NOT  BE  LIABLE  FOR  CONSEQUENTIAL  DAMAGES  ARISING  WITH  RESPECT  TO  THE 
PRODUCT, WHETHER BASED UPON NEGLIGENCE, TORT, STRICT LIABILITY, OR CONTRACT.

Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion or limitation may not apply to you. This warranty gives
you specific legal rights, and you may also have other rights which vary from state to state.

For the address of your nearest authorized service center, contact Marley Engineered Products in Bennettsville, SC, at 1-800-642-4328. Merchandise returned to the fac-
tory must be accompanied by a return authorization and service identification tag, both available from Marley Engineered Products. When requesting return authorization,
include all catalog numbers shown on the products.

01/11

Part No. 5200-2211-001

ECR 38636

470 Beauty Spot Rd. East
Bennettsville, SC  29512 USA

HOW TO OBTAIN WARRANTY SERVICE AND 
WARRANTY PARTS PLUS GENERAL INFORMATION

1. Warranty Service or Parts

1-800-642-4328

2. Purchase Replacement Parts

1-800-654-3545

3. General Product Information

www.marleymep.com

Note: When obtaining service always have the following:

1. Model number of the product
2. Date of manufacture
3. Part number or description

Summary of Contents for CPLAM

Page 1: ...ng or servicing this heater 7 This heater is not for residential or household use SAVE THESE INSTRUCTIONS CPL Series Convectors CPL Series Pedestal Convection Heater WARNING Installation Operation Mai...

Page 2: ...A continued Amperage Catalog Length Total 208V 240V 277V Number L Watts Ft Watts 1 3 1 3 1 2125 125 250 1 2 1 0 0 9 2188 188 375 1 8 1 6 1 4 2250 250 500 2 4 2 1 1 8 2375 28 375 750 3 6 3 1 2 7 2500...

Page 3: ...ith pedestal kits 6 Do not install heater below an electrical convenience recep tacle outlet 7 CAUTION Heater operates at high temperatures Keep electrical cords including telephone and computer cable...

Page 4: ...Note For ease of installation it is important that the sequence of operations indicated below be followed in order 1 Remove front cover by removing mounting screws Fig 3 2 Remove the top lock nut and...

Page 5: ...that the pedestals be held in place by the use of jigs during the concrete pour The jigs should be constructed of good quality 1 x 4 lumber as shown in Figure 5 The pedestals are installed in 5 1 7 1...

Page 6: ...ng a jumper wire not supplied between the two adjacent heaters 6 Replace front covers and secure with mounting screws Figure 3 OPERATION INSTRUCTIONS 1 This heater must be properly installed before it...

Page 7: ...7 Figure 7 Wiring Diagram...

Page 8: ...or wired or maintained in violation of the product s installation instructions All claims for warranty work must be accompanied by proof of the date of installation The customer shall be responsible...

Page 9: ...desconectador principal antes de instalar o prestar servicio a este calefactor 7 Este calefactor no es para uso residencial o dom stico GUARDE ESTAS INSTRUCCIONES Convectores Serie CPL Calefactor de...

Page 10: ...8250 250 2000 9 6 8 3 7 2 10125 125 1250 6 0 5 2 4 5 10188 10 188 1875 9 0 7 8 6 7 10250 250 2500 12 0 10 4 9 0 Prefijo CPLAS Modelo CPLAS H 5 1 2 D 3 Tabla A Tabla A cont Corriente A N mero de Longi...

Page 11: ...n licas o pl sticas etc Este calefactor est equipado con pedestales para montaje en el piso se suministran en una caja separada Vea las instrucciones que se proporcionan con los juegos de pedestal 6 N...

Page 12: ...cia de operaciones que se indica a continuaci n 1 Retire la cubierta frontal para ello quite los tornillos de montaje Fig 3 2 Quite la contratuerca superior y la tuerca de nivelaci n de cada pedestal...

Page 13: ...aria se recomienda mantener los pedestales en su sitio mediante el uso de soportes durante el vertido del hormig n Los soportes deben 13 1 7 16 CPLAS 1 9 16 CPLAM 25 1 8 CPLAS 24 7 8 CPLAM 28 Calefact...

Page 14: ...ministrado entre los dos calefactores adyacentes 6 Vuelva a colocar las cubiertas frontales y suj telas con los tornillos de montaje Figura 3 INSTRUCCIONES DE OPERACI N 1 Este calefactor debe instalar...

Page 15: ...A OTRO CALEFACTOR A OTRO CALEFACTOR TORNILLO DE PUESTA A TIERRA TORNILLO DE PUESTA A TIERRA TORNILLO DE PUESTA A TIERRA TORNILLO DE PUESTA A TIERRA CABLE N 10 CABLE N 10 ALIMENTACI N EL CTRICA AL INT...

Page 16: ...zaci n de retorno incluya todos los n meros de cat logo mostrados en los productos C MO OBTENER SERVICIO EN GARANT A PIEZAS DE REPUESTO E INFORMACI N GENERAL 1 Servicio o repuestos en garant a 1 800 6...

Page 17: ...lectrique arrivant au radiateur est bien d branch en amont l in terrupteur g n ral ou au panneau de service avant d intervenir pour installer ou d panner ce radiateur 7 Ce radiateur n est pas pour un...

Page 18: ...4375 4 375 1 500 7 2 6 2 5 4 4500 500 2 000 9 6 8 3 7 2 4564 564 2 250 10 8 6 2 9 4 5 4 8 0 4625 625 2 500 12 0 6 9 10 4 6 0 9 0 4750 750 3 000 14 4 8 3 12 5 7 2 10 8 5125 125 625 3 0 2 6 2 2 5188 18...

Page 19: ...avec des pieds pour montage au sol livr s en carton s par Consultez les instructions livr es avec ces kits de pieds 6 N utilisez pas le radiateur sous une prise d alimentation secteur 7 ATTENTION Le...

Page 20: ...tion des pieds Montage en surface sur sol existant Remarque Pour faciliter l installation il est important que la s quence des op rations indiqu es ci apr s soit suivie dans l ordre 1 Enlevez le couve...

Page 21: ...endant le versement du b ton Les soutiens doivent tre constitu s de bois d uvre 1 x 4 de bonne qualit comme montr en Figure 5 21 1 7 16 CPLAS 1 9 16 CPLAM 25 1 8 CPLAS 24 7 8 CPLAM 28 Radiateur 28 pou...

Page 22: ...ts 6 Remettez en place le couvercle frontal et maintenez le avec ses vis de fixation Voir la Figure 3 INSTRUCTIONS D UTILISATION 1 Le radiateur doit tre correctement install avant d tre utilis 2 Si le...

Page 23: ...LIMENTATION VERS INTERRUPTEUR DE COUPURE C BLAGE D USINE C BLAGE SUR SITE REMARQUE Pour le c blage interne individuel du radiateur r f rez vous l tiquette avec sch ma de c blage dans l unit FIL 10 VIS...

Page 24: ...e service de Marley Engineered Products Dans le cadre des limitations de cette garantie les unit s ne fonctionnant pas doivent tre renvoy es au centre de service agr Marley le plus proche ou directe a...

Reviews: