2.4
Control panels
1. Main switch; power supply ON / OFF.
2. Key switch; security against unauthorized use.
3. Light: 80 % fill level warning; if light flahes, compactor is filled 80 %.
4. Light dysfunction; motor-circuit switch F1 releases
– reducer shuts down automatically.
5. Socket: to connect power supply cable with a CEE-plug.
6. Emergency stop push-button, by pressing this button, the ram plate stops in its current position and
persons can be rescued.
7. ON button, ON push-button starts the reducing process (keep button pressed for 3-5 sec.). With the
integrated time-lag relay the reducer accomplishes about three pressing cycles automatically. The ON-
button flashes during operation.
8. Emergency off push-button, by pressing the button the ram plate stops in its current position. Resetting
operation is only possible by unlocking the emergency stop push-button. By pressing ON, the ram plate
moves back to the retraced position.
2.5
Power unit
1 Motor with hydraulic pump
2 4/3 directional valve
3 Oil tank
4 Filling and breather filter
5 Manometer
6 Oil deficiency switch
7 Control box