Page 14 of 39
BERINGER Middle East FZC
Fujairah Free Zone Phase III
Fujairah, U. A. E
Phone: +971 9 277 48 51
Homepage:
E-Mail: [email protected]
4.2
Electric system
Before opening the control box, detach system from electricity!
It is necessary to open the control box
in case the red light “fault” glows. In this case the motor circuit switch “F1”
actuates (usually failure of motor power supply or motor is overloaded).
In the power unit box, the control box is situated next to the hydraulic power unit. By a left quarter turn of the
locking mechanism the clear cover can be removed.
After cooling down the system
, the motor circuit switch “F1” unlocks automatically and the reducer is ready for
operation.
Before operation it is necessary to check motor’s power cable.
If the reducer doesn’t start, although feed cable works faultlessly and all emergency OFF push-buttons are
unlocked, the
“F2” fuse of the controller loop might be defect. In order to check this, the fuse cartridge situated at
the transformer setting has to be opened and the glass tube fuse is to be changed.
Watch out for the rubber seal, while closing the clear cover.
In order to close the power unit cover it is advisable to screw-on the 4 screws at the chamfer, to assure a better
grasp on the upper side.
5. APPENDIX
5.1
Technical Data
System
Chain-loader-truck
Type
reducer
x 4- MB
x 4-ergo - MB
Actuating power
KW
5,5
5,5
Fuse protection
A
16 A delay*
16 A delay*
Length compactor part
mm
1450
1450
Hopper height
mm
1680
1310
Upper feed opening
mm
1200 x 1500
1200 x 1500
Lower feed opening
mm
800 x 1500
800 x 1500
Ram capacity / stroke
cbm
1,25
1,25
Plunger stroke
mm
1130
1130
Retraction depth
mm
280
280
Compaction force (at 225 bar)
kN
330
330
Cycle time
sec.
33
33
Hydraulic oil
Ltr.
35
35
Power supply
V
400 V / 50 Hz
400 V / 50 Hz
Empty weight
kg
3000 (10 cbm)
3000 (10 cbm)
Max. total weight
kg
10.000
10.000
* The fuse protection of the mobile compactor is control circuit 0,4 A delay. The fuse protection of
the power circuit, as described in chapter 3.1 has to be provided by the customer. Charging rate
of motor is 11,7 A.