4.0 General information and service notes
4.1 Change control fuses
If a control fuse is broken, it is impossible to start the reducer. Furthermore the emergency
deliverance is not working.
In order to change the fuses, the power unit lid has to be opened. The control fuses are located
in the control box at the transformer T1.
Please only use fuses with the following technical data:
For 230V:
0,4 A delay; size 32x6mm
For 24V:
0,5 A delay, size 32x6mm
4.2 Electricity supply
Operating voltage 3x400V, network configuration: TN
– C – S – network
CEE socket 16A (32A), protection with 3-pole circuit breaker.
3x16A (32A) delay C/D over connected upstream CFGI with 0,03A Trip current.
Please check connecting cables, sockets and couplings before connecting. The sockets or
couplings have to be put into the fixing device until the lids are locked.
Loose plug connections or short interruptions in power supply lead to damages in the control
system, increased wear or shortened life-time cycle of the reducer.