37
2000
2126 The value of this parameter is defined by Par. 9097.
0 Disabled 1 General
Pump 2 CH Pump 3
DHW Pump 4 System
Pump 5 Cascade
Pump 6 Alarm Relay
7 Filling Valve 8 LPG
Tank 9 External Ignit-
er 10 Air Damper 14
Alarm Burner CC 15
Status Burner CC 17
Antilegionella pump
De-
fined
by
Par.
9097
2127 The value of this parameter is defined by Par. 9097.
0 Disabled 1 General
Pump 10 Air Damper
11 HIS 12 Modulating
Pump
De-
fined
by
Par.
9097
2128 The value of this parameter is defined by Par. 9097.
0 Disabled 1 General
Pump 2 CH Pump 3
DHW Pump 4 System
Pump 5 Cascade
Pump 6 Alarm Relay
7 Filling Valve 8 LPG
Tank
De-
fined
by
Par.
9097
2129 Defines the type of flow sensor used.
Bitron, Huba: DN8,
DN10, DN15, DN15,
DN20, DN25
Huba
DN25
2133 Defines the delta T set for the operation of the modulating
circulator.
5…40
15
°C
2134
Defines the time in seconds from the moment the burner is
switched on to start the modulation of the circulator and
obtain the delta T specified in Par. 2133.
0…255
120
Sec.
2135 Defines the PWM circulator model installed.
Wilo Yonos , Salm-
son, Grunndfos
Grund-
fos
2136
Defines if the module pump is on modulating mode or if it is
made run at a fixed speed (on a percentage at the max
speed).
On/Off Modulating
Fixed 20… 100%
Modu-
lating
2137 Defines the percentage of speed that sets the minimum
speed that the circulator can reach during modulation.
0…100
30
%
2138
Value can vary depending on appliance configuration based
on Par. 9097 and 9098. This value is calculated by the
board, which, based on an internal logic, defines as a single
number the settings of Par. 9097 and 9098.
0…255
De-
pends
on
boiler
model
2139
Activates air purge in the system. To activate the air purge,
switch on the thermal module and change the parameter
from "No" to "Yes". Wait a minute. Turn off and on again. At
this point at start-up, the thermal module will perform the
automatic purge procedure (duration about 20 minutes).
With the parameter set to "Yes", the procedure is performed
each time the thermal module is switched off and back on
via its own main switch. The value must be "No" if no purge
procedure is required when the thermal module is started.
Yes, No
No
2140 Defines the flow level under which value the thermal module
is turned off. The value may vary according to the model.
0.0…100
De-
pends
on
boiler
model
l/min
2201 Enable Heating
Enable/Disable
Ena-
ble
-
2202 Enable Heating
Enable/Disable
Ena-
ble
-
2203 Sets the Service reminders
Off/On/Reset
Off
-
2204 Days for Service
30/35/40…./1275
1000 days