15 - PROGRAMMING PARAMETERS
This boiler incorporates a new generation of electronic boards that, by setting/
modifying operating parameters, allow the boiler to be personalised to satisfy
various system and/or user requirements. The programmable parameters are
shown in the table on the next page.
The parameters must be programmed with the boiler in the OFF position.
To do this, press the button until the display shows “- -” (Fig. E).
During parameter modification operations, the “select functions” button
acts as an ENTER (confirm) button, the button acts as an ESCAPE
(escape) button. If no confirmation is given within 10 seconds, the value is
discarded and returns to the previously set one.
Setting the password
Press and hold down the select functions button and the button together for
about 10 seconds. The display will look like Fig. F. Enter the password for
accessing the parameter modifications function by turning the domestic hot
water temperature selector to obtain the required value. The password for
accessing the parameter programming function is located on the back side of
the control panel. Confirm by pressing ENTER.
Modifying parameters
Turn the domestic hot water temperature selector (Fig. G) to sequentially scroll
the two-figure codes of the parameters indicated in the table. After identifying
the parameter you wish to modify, proceed as follows:
- press ENTER to access the parameter modification function. When ENTER
is pressed, the previously set value starts flashing (Fig.H)
- turn the domestic hot water temperature selector to change the value
- press ENTER to confirm the new value. The digits stop flashing (Fig.I)
- press ESCAPE to exit.
The boiler returns to the “- -” (OFF) status.
To reset, press the button (Fig. E).