26
EXCLUSIVE
- setting
TIME & DATE
12
17
:
ENTER TIME AND DATE
TIME & DATE
USE THE ARROWS TO MODIFY
18 / 11 / 2013
ENTER TIME AND DATE
TIME & DATE
USE THE ARROWS TO MODIFY
- setting the operating mode of the REC10:
MASTER: select this option when the REC10 is also a MACHINE
INTERFACE
.
- configuration selection:
FROM AKM: to reset the current boiler configuration on REC10 MASTER
and finish the operation
NEW: to set a new system configuration restoring the factory setting of
the parameters
NEW
FROM AKM
SELECT THE TYPE
OF CONFIGURATION
NEW
SELECT THE TYPE OF
CONFIGURATION
FROM AKM
Whenever a “NEW” configuration is selected, proceed as follows:
- select REC10 functionality:
ON BOARD: if the REC10 is used only as a system interface and not as
an ambient regulator
AMBIENT: if the REC10 is used as a system interface and also as an
ambient regulator of the zone where it is installed
ON BOARD
AMBIENT
WHERE IS
THE REC10 INSTALLED?
BOILER
ON BOARD
WHERE IS THE REC10 INSTALLED?
AMBIENT
BOILER
- select the type of boiler
INSTANTANEOUS (the boiler is the combined
variety)
PLANT
CH ONLY
INSTANTANEOUS
STORAGE TANK
SELECT THE PLANT
CONFIGURATION
INSTANTANEOUS
HW TANK
CH ONLY
SELECT THE PLANT CONFIGURATION
PLANT
- select FL
OW SWITCH
.
PLANT
FLUX SWITCH
FLUX METER
PLANT
PLANT
FLUX SWITCH
FLUX METER
PLANT
PLANT
FLOW METER
FLOW SWITCH
-
O
nce the guided procedure has finished, the REC10 will go to the initial
screen.
Continue with the configuration as follows:
-
access the technical parameters as explained in the section
to the technical parameters”, using the password SERVICE
- s
elect PARAMETERS with the
“up”
and
“down”
keys, confirming the
selection
-
next change the following parameters:
AUTO WATER FILL ENABLE
: set to 1.
Then proceed with the reprogramming of the boiler, carrying out the
operations described in the section
.
5.21 Replacing the REC10 MASTER
b
The system’s configuration operations need to be carried out by
professionally qualified personnel of the Technical Assistance Centre
.
When replacing the REC10 MASTER, at the subsequent restart it displays
an initial screen with the firmware revision.
Pressing
“ok”
starts a guided procedure for configuring the system, see
. Follow the procedure and carry out the
FROM AKM type of configuration
.
MULTI ZONE CONTROLLER
REC10 V01.26
PRESS ANY KEY
TO CONTINUE
PRESS ANY KEY TO
CONTINUE
SELECT THE TYPE
OF CONFIGURATION
NEW
FROM AKM
NEW
FROM AKM
SELECT THE TYPE OF
CONFIGURATION
5.22 Replacing the AKM01 board
The configuration operations should be carried out by
professionally qualified
personnel of the Technica
l Assistance
Centre. The systems continually
carries out a consistency control between the saved configuration data on
the AKM01 electronic board and those saved in the REC10; therefore, when
replacing the AKM01 electronic board, it can happen that the system detects
an inconsistency between the data saved on the AKM01 and that in the
REC10. In this case, the latter will ask the user which of the two configurations
is to be considered valid; selecting to recuperate the configuration from the
REC10 itself it is possible to avoid reconfiguring the machine:
- select REC10 with the
“up”
and
“down”
keys, confirming the selection.
FROM AKM
REC10
SELECT THE TYPE
OF CONFIGURATION
FROM AKM
SELECT THE TYPE OF
CONFIGURATION
5.23 Parameters combustion check
Although the parameters referring to the new combustion control
system ACC (Activate Combustion Control) are preset in the factory, the
simultaneous replacement of both electronics boards (AKM and REC 10
MASTER) could make necessary to re-programming these parameters.
-
Access the technical parameters as explained in the section
setting the password
INSTALLER
-
Select COMBUSTION MONITORING
with the
“up”
and
“down”
keys,
confirming the selection