4 CONTROL PANEL (REC10)
The REC10 remote control has the function of machine interface,
displaying the system and providing access to the parameters.
The middle of the main screen displays the temperature of the domestic
hot water probe, unless there is a heat request is in progress, in this
case the delivery temperature of the boiler at that particular time is
displayed.
The value expressed in bar refers to the system’s water pressure.
The top of the screen shows the information regarding the current date
and time, as well as the outdoor temperature, if available.
On the left and right sides are displayed the icons indicating the status
of the system; their meaning is as follows.
Pressing the keys
“up”
and
“down
”
it is possible to choose from among
the following options:
•
PLANT:
a scrolling message on the display can indicate the temperature
of the domestic hot water probe rather than the flow sensor of the boiler
•
STATE (when the SYSTEM SCREEN is selected):
to set the status
of the boiler (OFF, HOT WATER ONLY
or
HEATING AND HOT WATER
)
and, when managed by the room thermostat, the operating mode of
the main area in heating mode (ON or OFF if the time schedule is
disabled, AUTO according to hourly programming, MANUAL or OFF if
programming timing is enabled)
•
SET:
to establish the heating or hot water setpoint value or for activating
preheating
•
INFO:
to display the value of the system variables
•
MENU:
to access the system’s configuration menus
FRI
18/05/2013
12:17
MENU
INFO
SET
PLANT
HOT WATER TEMPERATURE
STATE
42
°C
P
1.3 bar
MENU
STATE
SET
INFO
PLANT
HOT WATER TEMPERATURE
FRI
LED
REC10
This icon indicates that the OFF operating status mode has been set. Each ignition request is ignored except for the anti-freeze function. The pump
anti-lock, 3-way valve and anti-freeze function remain active.
This icon indicates that
HEATING AND HOT WATER mode has been selected (HEATING function enabled). If a heating request from the main
zone is in progress, the icon will be flashing.
This icon indicates that the circuit for domestic hot water production is enabled. When a domestic hot water request is in progress, the icon flashes.
The P at the top of the domestic hot water icon indicates that the boiler preheating function is enabled; the P when flashing indicates that a preheating
request is in progress.
When the “central heating programming timing” is enabled this icon indicates that the system heating (main zone) is in AUTOMATIC mode (the
management of the heating requests follows what has been set with the timer).
If the heating function is not enabled during the current time frame, the icon will be crossed out.
When the “central heating programming timing” is enabled this icon indicates that the system heating (main zone) is in MANUAL mode (the
management of the heating requests does not follow what has been set with the programming timing, but it is always active).
OFF
This icon indicates that the system (main zone) has been set to off (not active).
This icon indicates that the system is detecting the presence of a flame.
This icon indicates the presence of an anomaly, and is always flashing.
LED
Light signal indicating the operating status of the boiler. Can be red or green (see specific paragraph)
REC10
Boiler control panel
Key area
ok= confirm
back= return to the previous screen
cancel selection
return to the main screen (press > 2 sec.)
up=
allows you to choose between the options PLANT-STATE-SET-INFO-MENU and to
surf through the
submenus scrolling upwards
down=
allows you to choose between the options PLANT-STATE-SET-INFO-MENU and to
surf through the
submenus scrolling down
The configuration MENU is organised with a multi-level tree structure. With
the
“ok”
key you can access the selected submenu, with the
“up”
and
“down
”
keys it is possible to navigate through the submenus, while the
“back”
key takes you back to the previous level.
An access level has been fixed for each submenu: USER level, always
available; TECHNICAL level, password protected.
Below is a summary of the MENU tree structure of the REC10.
b
Some of the information might not be available on the REC10
depending on the access level, the status of the machine or the
system configuration
.