2 .6 Connecting the low temperature
thermostats
The
Connect LE
are equipped with a low temperature limit thermostats
(TB) that protect the zones of low-temperature above 55 °C.
b
Do not connect the low temperature limit thermostats (TB) in case of
high temperature system.
For installations on low temperature system (floor) to choose one of the
following links:
- boiler - connect the low temperature thermostat TB, brown wires (MA)
and blue (BL), the input of TBT boiler (see installation manual for con-
nection and operation of the boiler in case of intervention of at least one
of the thermostats TB).
- Connect - connect the low temperature thermostat TB inside the electri-
cal panel of the module, removing jumper purple (VI) and connecting the
wires brown (MA) and blue (BL) in place of the jumper previously remo-
ved.
In case of intervention of at least one of the thermostats TB will stop the
power to all the circulators and the request to the boiler until normal oper-
ating conditions are restored.
VI
RS
NE
BI
MA
MA
MA
MA
TB
MA
BL
2 .7 Electrical connections
The
CONNECT LE
is prearranged with rubber cable feed-throughs
(1) located in the top section of the box allowing wiring to be passed
through.
1
3
4
Below is an explanation of how to correctly connect the
CONNECT LE
to the various devices and the boiler.
b
Before carrying out any electrical intervention, set the main sys-
tem switch to “off”.
Connecting the
CONNECT LE
to the electrical power supply
- Pass the cable (2) which comes out of the electrical connection
box (3) through the cable feed-through (1) and connect it to the
electrical power supply (phase-neutral-earth) making sure not
to connect it below the boiler fuse.
1
2
3
Access to the CONNECT LE connection terminals.
- To access the
CONNECT LE
connection terminals, loosen the
four screws (4) and remove the cover (3).
1
3
4
Connecting the CONNECT LE to the ambient thermostats/chro-
no-thermostats
- Carry out the connections of the ambient thermostats (TA) and/
or chrono-thermostats (CT) of each zone, as indicated in the di-
agrams below. Before connection, eliminate the relative jumper
(TA1,TA2 or TA3).
CONNECT 3D LE
CONNECT 2D LE
MA
BL
TBT3
TBT2
TBT1
MA
MA
2
3
4
5
6
7
TA2 NE
TA1 RS
TA3 BI
8
9
1
RS
RS
MA
BL
MA
MA
BL
BL
BL
GI/VE
GI/VE
GI/VE
blu
MA
VI
MA
NE
GI/VE
GI/VE
GI/VE
GI/VE
BL
BL
MA
MA
BL
BL
BL
BL
BL
BL
BI
BI
RS
MA
MA
NE
NE
BL
MA
MA
MA
TA2 dopo aver
rimosso ponticello
nero in morsettiera
TA3 dopo aver
rimosso ponticello
bianco in morsettiera
TA1 dopo aver
rimosso ponticello
rosso in morsettiera
TBT1 - TBT2 - TBT3
dopo aver rimosso
ponticello viola in
morsettiera
GI/VE
P2
BL
MA
GI/VE
P1
BL
MA
MA
BL
P3 GI/VE
BL
BL
BL
Cavo ingresso
di rete 230V
BI
MA
MA
BL
TBT1
TBT2
2
3
5
6
TA 1 RS
MA
7
1
BL
Cavo ingresso
di rete 230V
MA
GI/VE
GI/VE
MA
MA
BL
BL
GI/VE
MA
BL
BL
MA
BL
4
TA 2 NE
VI
MA
BL
RS
BL
NE
BL
BL
GI/VE
MA
GI/VE
BL
BL
TA1 dopo aver
rimosso
ponticello ROSSO
in morsettiera
TA2 dopo aver
rimosso ponticello
NERO
in morsettiera
GI/VE
P2
BL
MA
GI/VE
P1
BL
MA
TBT1 - TBT2
dopo aver
rimosso
ponticello
VIOLA
in morsettiera