19
Mynute Boiler Green B.S.I. E
Multigas table
DESCRIPTION
Methane gas
(G20)
Propane
(G31)
Lower Wobbe index (at 15°C-1013 mbar)
MJ/m
3
S
45,67
70,69
Net Calorific Value
MJ/m
3
S
MJ/KgS
34,02
-
88
46,34
Supply nominal pressure
mbar
(mm W.C.)
20
203,9
37
377,3
Supply minimum pressure
mbar
(mm W.C.)
8
81,6
Mynute Boiler Green 25 B.S.I. E
Burner: number of nozzles - diameter of nozzles - lenght
n° - mm - mm
1 - 63 - 130
1 - 63 - 130
Diaphragm: number of holes - diameter of holes
n° - mm
1 - 5,6
1 - 4,3
Heating maximum gas capacity
Sm
3
/h
2,64
kg/h
1,94
DHW maximum gas capacity
Sm
3
/h
2,64
kg/h
1,94
Heating minimum gas capacity
Sm
3
/h
0,63
kg/h
0,47
DHW minimum gas capacity
Sm
3
/h
0,63
kg/h
0,47
Numbers of fan revolutions at slow start
revs/min
4.000
4.000
Maximum number of fan revolutions (CH)
revs/min
7.100
7.000
Maximum number of fan revolutions (DHW)
revs/min
7.100
7.000
Minimum number of fan revolutions (CH)
revs/min
2.100
2.100
Minimum number of fan revolutions (DHW)
revs/min
2.100
2.100
Mynute Boiler Green 35 B.S.I. E
Burner: number of nozzles - diameter of nozzles - lenght
n° - mm - mm
1 - 63 - 140
1 - 63 - 140
Diaphragm: number of holes - diameter of holes
n° - mm
2 - 3,8
2 - 3,05
Heating maximum gas capacity
Sm
3
/h
3,66
kg/h
2,69
DHW maximum gas capacity
Sm
3
/h
3,66
kg/h
2,69
Heating minimum gas capacity
Sm
3
/h
0,37
kg/h
0,48
DHW minimum gas capacity
Sm
3
/h
0,37
kg/h
0,48
Numbers of fan revolutions at slow start
revs/min
3.300
3.300
Maximum number of fan revolutions (CH)
revs/min
6.000
5.900
Maximum number of fan revolutions (DHW)
revs/min
6.000
5.900
Minimum number of fan revolutions (CH)
revs/min
1.200
1.900
Minimum number of fan revolutions (DHW)
revs/min
1.200
1.900