8
Product information
6003295_g – 19.03.2019
2.5
Installation variants and installation dimensions
The device is suitable for two installation variants:
y
Installation in wall cabinets without cabinet base
y
Installation in the installation frame (optional)
Dimensions for installation in wall cabinets:
y
Width min. 600 mm (BEH 60 FLU) or
900 mm (BEH 90 FLU).
y
Depth 300 - 350 mm.
y
Height (cabinet interior) min. 360 mm.
y
Height (cabinet interior) with versions with recirculated air
filter permalyt BUR 125 (optional) min. 730 mm (including
60 mm for the air outlet).
y
Side wall thickness 16 - 19 mm.
y
Distance from the device to the wall max. 40 mm.
Dimensions for installation in the installation frame:
y
Width min. 800 mm (BEH 60 FLU) or
1000 mm (BEH 90 FLU).
y
Depth min. 380 mm.
y
Height (cabinet interior) min. 360 mm.
y
Height (cabinet interior) with versions with recirculated air
filter permalyt BUR 125 (optional) min. 730 mm (including
60 mm for the air outlet).
y
Distance from the device to the wall max. 40 mm.
Particulars with the cabinet depths:
y
Cabinet depth 300 - 310 mm (A):
Angle trim strip at front (modification required).
D
“3.5.4 Install the device” (page 14).
y
Cabinet depth 311 - 350 mm (B):
Angle trim strip at rear (as delivered).
Spice rack:
y
Installation possible above a height of 360 mm.
y
Depth max. 120 mm.
y
Not possible with versions with recirculated air filter
permalyt BUR 125.
With use of the device in recirculated air mode:
☞
Make sure that the kitchen units are equipped with a
ventilation outlet (e.g. with a stainless steel cover grill).
2.5.1
Installation with recirculated air mode
600 / 900
≥ 360
245
≤ 120
=
=
≥ 460
A=300-310
B=311-350
2.5.2
Installation with extracted air mode -
exhaust air upwards
600 / 900
≥ 360
A=300-310
B=311-350
B=232
=
=
≥ Ø 135
181
A=78
367
23