14
Installation
6003295_g – 19.03.2019
3.5.4
Install the device
Installation in wall cabinets without a cabinet base is
described in the following.
With installation in the installation frame (e.g. with suspended
systems), it is necessary to observe special requirements.
D
“3.5.5 Installation in the installation frame (optional)”
(page 19).
x
=
=
=
=
Safety distance (x):
y
Recommendation 550 mm.
y
With gas hobs, at least 650 mm.
Distance from the device to the wall:
y
Max. 40 mm.
In order to collect the cooking fumes from the front hob
plates:
y
Work top max. 600 mm deep.
☞
Determine the installation position.
☞
Make sure that the safety distance is complied with.
Installation without mounting aid frames
With the following versions, the fastening brackets are
mounted directly on the cabinet:
y
BEH 60 FLU
y
BEH 90 FLU – with installation in cabinets with centre
walls
Cabinet depth 311 - 350 mm
123
70,5
55
50
45
222
16 - 19
311 - 350
123
70,5
55
50
45
88,5
300 - 310
< 120
Cabinet depth 300 - 310 mm
The installation of a faceplate behind the front is not possible.
123
70,5
55
50
45
222
16 - 19
311 - 350
123
70,5
55
50
45
88,5
300 - 310
< 120
☞
Determine the position of the fastening brackets in the
cabinet.
Summary of Contents for Firstline Unseen BEH 60 FLU