Replacement of oil pump
Removal and installation
1.
Break the main current and disconnect the Euro plugs from the burner.
2.
Undo the oil lines from the pump.
3.
Loosen the screws (O) and pull out the oil pump
4.
Move the pump coupling to the new pump and set the same distance
between (P) the pump and the pump coupling as before in order to
avoid pressure on the pump seal.
5.
Install the oil pump on the burner and tighten the screws (O). (It is
important that the pump shaft splines align correctly in the pump
coupling).
6.
Fit the oil lines.
7.
Fit the Euro plugs and turn on the main current.
8.
Bleed the pump, start the burner and set the correct oil pressure.
9.
Check combustion. *
Note:
*
When servicing/replacing components that affect combustion, an
analysis and soot test shall be carried out on the installation.
!
Use caution when operating the burner, surfaces may be hot.
!
When servicing oil bearing components, check for oil leakage
when the burner is commissioned after servicing.