background image

Dimensions

171 225 16  07-01

TECHNICAL DATA

Electrode adjustment

Because of different boiler types 
existing on the market, with varying 
combustion chamber designs, it is 

not possible to state a definite spray 

angle or spray pattern.

Recommended nozzle

Note that the spray angle and the 
spray pattern change with the pump 
pressure.

Output range and nozzles recommended

The net calorific value of 11,86 kWh/kg for light oil has been used.

Burner tube

Length of burner 

tube

Incl. flange A 

Measure B

Incl. flange B 

Measure B

Incl. flange C 

Measure B

Incl. flange D 

Measure B

KA

94

56

69

77

76

KA

147

109

122

130

129

KA

197

159

172

180

179

KA

224

186

199

207

206

Burner tube

Oil capacity

Outputy

Recommended

Nozzle 

Recommended 
Pump pressure

kg/h

kW

Mcal/h

Angle

Type

Bar

KA

2,0-5,6

24-66

20-57

60°, 80°

H, S

10

ST 120 KA

2,7-3,3

0,5-1,5

8,0-9,0

B

194

275

148

ø89

169

54

229

Summary of Contents for ST120KA

Page 1: ...178 009 15 Installation and maintenance instruction BENTOFLEX ST120KA...

Page 2: ...ables 5 Nozzle assembly 6 Nozzle 7 Brake plate 8 Blast tube 9 Ignition electrodes 10 Connecting pipe 11 Air damper 12 Solenoid valve 13 Pump 14 Drive coupling 15 Indication air damper 16 Fan wheel 17...

Page 3: ...utput range and nozzles recommended The net calorific value of 11 86 kWh kg for light oil has been used Burner tube Length of burner tube Incl flange A Measure B Incl flange B Measure B Incl flange C...

Page 4: ...TECHNICAL DATA 171 215 76 07 01 Flange A 10 3 25 130 150 89 7 Flange C 10 125 90 4 Flange D 125 150 10 3 90 5 12 Flange B 89 5 12 136 150 Dimensions...

Page 5: ...ombustion free of soot By this procedure an optimum adjust ment is obtained If larger nozzles are used the preadjustment of the air volume must be increased Condensation in chimney A modern burner wor...

Page 6: ...MAINTENANCE OF OIL BURNER Warning Before doing any service switch off power at the main switch and cut off the oil supply 171 305 68 07 01 Service of burner head and nozzle assembly...

Page 7: ...R1 Photoresistor S3 Main switch T1 Ignition transformer Y1 Solenoid valve X1 Plug in contact burner X2 Plug in contact boiler Outer electrical connection Mains connection and fuses in accordance with...

Page 8: ...d by means of the main switch or the thermostat a new start takes place when the conditions in accordance with point 1 are fulfilled The oil burner control cuts out A red lamp in the control is lit Pr...

Page 9: ...mercial quality according to current standards On commis sioning with an empty tube system the oil pump should not be run without oil for more than 5 min a condition is that the pump is being lubricat...

Page 10: ...stances the oil pressure falls below the set value andthevalveclosesagainstthe returnside R bymeansofthe diaphragm D andgoesintostarting position This can be remedied by Reducing the pump pressure Red...

Page 11: ...93 9 71 115 99 10 24 121 104 10 73 127 109 3 00 9 98 118 102 10 59 126 108 11 16 132 114 11 71 139 119 3 50 11 65 138 119 12 35 146 126 13 03 154 133 13 66 162 139 4 00 13 31 158 136 14 12 167 144 14...

Page 12: ...1 21 133 114 11 67 138 119 12 11 144 123 12 53 148 128 3 00 12 23 145 125 12 73 151 130 13 21 157 135 13 67 162 139 3 50 14 27 169 145 14 85 176 151 15 42 183 157 15 95 189 163 4 00 16 31 193 166 16 9...

Page 13: ...magnetic valve Burner fails to start Lamp not lit Motor runs Burner runs to lockout Fuse has blown Appliance thermostat has not reset Appliance overheat device has operated Control relay or photocell...

Page 14: ...B20 B30 B40 B45 02119815004 B50 B60 B70 B80 040588622001 B55 040588622002 B65 Enertech AB declares under sole responsibility that the above mentioned product is in conformity with the following stand...