background image

171 505 44  07-01

Gph

12

13

14

15

kg/h 

kW 

Mcal/h kg/h 

kW 

Mcal/h kg/h 

kW 

Mcal/h kg/h 

kW 

Mcal/h

0,40

1,63

19

17

1,70

20

17

1,76

21

18

1,82

21

18

0,50

2,04

24

21

2,12

25

22

2,20

26

22

2,28

27

23

0,60

2,45

29

25

2,55

30

26

2,64

31

27

2,73

32

28

0,65

2,65

31

27

2,75

33

28

2,86

34

29

2,96

35

30

0,75

3,08

36

31

3,18

38

32

3,30

39

34

3,42

40

35

0,85

3,47

41

35

3,61

43

37

3,74

44

38

3,87

46

39

1,00

4,08

48

42

4,24

50

43

4,40

52

45

4,56

54

46

1,10

4,48

53

46

4,67

55

48

4,84

57

49

5,01

59

51

1,20

4,89

58

50

5,09

60

52

5,29

63

54

5,47

65

56

1,25

5,10

60

52

5,30

63

54

5,51

65

56

5,70

68

58

1,35

5,50

65

56

5,73

68

58

5,95

70

61

6,15

73

63

1,50

6,11

72

62

6,36

75

65

6,60

78

67

6,83

81

70

1,65

6,73

80

69

7,00

83

71

7,27

86

74

7,52

89

77

1,75

7,14

85

73

7,42

88

76

7,71

91

79

7,97

94

81

2,00

8,18

97

83

8,49

101

86

8,81

104

90

9,12

108

93

2,25

9,18

109

94

9,55

113

97

9,91

117

101

10,26

122

105

2,50

10,19

121

104

10,61

126

108

11,01

130

112

11,39

135

116

2,75

11,21

133

114

11,67

138

119

12,11

144

123

12,53

148

128

3,00

12,23

145

125

12,73

151

130

13,21

157

135

13,67

162

139

3,50

14,27

169

145

14,85

176

151

15,42

183

157

15,95

189

163

4,00

16,31

193

166

16,97

201

173

17,62

209

180

18,23

216

186

4,50

18,35

217

187

19,10

226

195

19,82

235

202

20,51

243

209

5,00

20,39

242

208

21,22

251

216

22,03

261

225

22,79

270

232

5,50

22,43

266

229

23,34

277

238

24,23

287

247

25,07

297

256

6,00

24,47

290

249

25,46

302

260

26,43

313

269

27,49

326

280

6,50

26,51

314

270

27,58

327

281

28,63

339

292

29,63

351

302

7,00

28,55

338

291

29,70

352

303

30,84

366

314

31,91

378

325

7,50

30,59

363

312

31,83

377

324

33,04

392

337

34,19

405

349

8,00

32,63

387

333

33,95

403

346

35,25

418

359

36,47

432

372

8,50

34,66

411

353

36,07

428

368

37,45

444

382

38,74

459

395

9,00

36,71

435

374

38,19

453

389

39,65

470

404

41,02

486

418

NOZZLE TABLE

The table applies to oil with a viscosity of 4,4 mm

2

/s (cSt) with density 830 kg/m

3

.

Burner with preheater

Consider that on preheating the oil quantity is reduced by 5-20% depending on.
-  Rise in temperature at the nozzle
-  Design of nozzle
-  Capacity (high capacity - small difference)

2(2)

Pump pressure bar

Summary of Contents for ST120KA

Page 1: ...178 009 15 Installation and maintenance instruction BENTOFLEX ST120KA...

Page 2: ...ables 5 Nozzle assembly 6 Nozzle 7 Brake plate 8 Blast tube 9 Ignition electrodes 10 Connecting pipe 11 Air damper 12 Solenoid valve 13 Pump 14 Drive coupling 15 Indication air damper 16 Fan wheel 17...

Page 3: ...utput range and nozzles recommended The net calorific value of 11 86 kWh kg for light oil has been used Burner tube Length of burner tube Incl flange A Measure B Incl flange B Measure B Incl flange C...

Page 4: ...TECHNICAL DATA 171 215 76 07 01 Flange A 10 3 25 130 150 89 7 Flange C 10 125 90 4 Flange D 125 150 10 3 90 5 12 Flange B 89 5 12 136 150 Dimensions...

Page 5: ...ombustion free of soot By this procedure an optimum adjust ment is obtained If larger nozzles are used the preadjustment of the air volume must be increased Condensation in chimney A modern burner wor...

Page 6: ...MAINTENANCE OF OIL BURNER Warning Before doing any service switch off power at the main switch and cut off the oil supply 171 305 68 07 01 Service of burner head and nozzle assembly...

Page 7: ...R1 Photoresistor S3 Main switch T1 Ignition transformer Y1 Solenoid valve X1 Plug in contact burner X2 Plug in contact boiler Outer electrical connection Mains connection and fuses in accordance with...

Page 8: ...d by means of the main switch or the thermostat a new start takes place when the conditions in accordance with point 1 are fulfilled The oil burner control cuts out A red lamp in the control is lit Pr...

Page 9: ...mercial quality according to current standards On commis sioning with an empty tube system the oil pump should not be run without oil for more than 5 min a condition is that the pump is being lubricat...

Page 10: ...stances the oil pressure falls below the set value andthevalveclosesagainstthe returnside R bymeansofthe diaphragm D andgoesintostarting position This can be remedied by Reducing the pump pressure Red...

Page 11: ...93 9 71 115 99 10 24 121 104 10 73 127 109 3 00 9 98 118 102 10 59 126 108 11 16 132 114 11 71 139 119 3 50 11 65 138 119 12 35 146 126 13 03 154 133 13 66 162 139 4 00 13 31 158 136 14 12 167 144 14...

Page 12: ...1 21 133 114 11 67 138 119 12 11 144 123 12 53 148 128 3 00 12 23 145 125 12 73 151 130 13 21 157 135 13 67 162 139 3 50 14 27 169 145 14 85 176 151 15 42 183 157 15 95 189 163 4 00 16 31 193 166 16 9...

Page 13: ...magnetic valve Burner fails to start Lamp not lit Motor runs Burner runs to lockout Fuse has blown Appliance thermostat has not reset Appliance overheat device has operated Control relay or photocell...

Page 14: ...B20 B30 B40 B45 02119815004 B50 B60 B70 B80 040588622001 B55 040588622002 B65 Enertech AB declares under sole responsibility that the above mentioned product is in conformity with the following stand...

Reviews: