Bentel Security BW-ODT Manual Download Page 3

D-304957 BW-ODT Installation Instructions 

Important: 

Reliable reception must be assured. Therefore, "poor" signal strength is not acceptable. If you receive a "poor" signal from the 

detector, relocate it and re-test until a "Good" or "Strong" signal strength is received.

 

Note:

 For detailed Diagnostics Test instructions refer to the control panel Installer's Guide.

 

The LED blinking, described above, is operative only in Local diagnostic mode. Upon each full detection (LED lights steadily for 2 seconds), 

the control panel receives the alarm. If required, perform the detector's horizontal / vertical adjustments (see section 2.1 and Figure 3). 

Important:

 Instruct the user to perform a walk test at least once a week, to verify proper operation of the detector. 

D. 

Place a piece of cardboard on the detector’s front side to deliberately mask the optical window. Verify that after 2 minutes, the yellow LED lights 

continuously (see Table 3 below) and the alarm control panel receives the masking alarm. 

E.

  Remove the masking from the detector’s front side. Verify that the LED turns off. 

Table 3 - LED operation 

LED Indications 

Event 

Red LED blinks 

Stabilization (warm-up 60 sec) 

Red LED ON 0.2 sec. 

Tamper open / close 

Red LED blinks twice 

One quad PIR detection in diagnostic mode 

Red LED ON 2 sec. 

Intruder alarm 

Yellow LED ON 

AM detection – diagnostic mode 

Yellow LED blinks slowly (0.2 sec. ON, 30 sec. OFF) 

AM detection – Normal mode 

3. COMPLIANCE WITH STANDARDS 

 

Europe:

 EN 300220, EN 301489, EN 62368-1, EN 60950-22, EN 50130-4, EN 50130-5, EN 50131-2-2, EN 50131-5-3, EN 50131-6 

Type C. 
Hereby, Bentel Security S.r.l. declares that the radio equipment type BW-ODT is in compliance with Directive 2014/53/EU. 

The full text of the EU declaration of conformity is available at the following internet address

http://www.b

entelsecurity.com/dc

Certified by Norwegian accredited certification body Applica Test & Certification AS in accordance with EN 50131-2-2, EN 

50131-5-3, EN 50131-6, EN 50130-4, and EN 50130-5. 

UK

: This product is suitable for use in systems installed to conform to PD6662 at Grade 2 and environmental class IV. 

BS8243 

 

 

W.E.E.E. Product Recycling Declaration

 

For information regarding the recycling of this product you must contact the company from which you originally purchased it. If you 

are discarding this product and not returning it for repair then you must ensure that it is returned as identified by your supplier. This 

product is not to be thrown away with everyday waste. 

Directive 2012/96/EC Waste Electrical and Electronic Equipment. 

APPENDIX: SPECIFICATIONS 

OPTICAL

 

 

Black Mirror Max. Coverage

 

Up to 12 m (40 ft) / 90°

 

Detector Technology

 

8 independent quad PIR detectors operating in true Quad configuration

 

(See figure. 6)

 

Pet Immunity

 

Up to 18 Kg (40 lb)

 

ELECTRICAL

 

 

Input Power

 

Two 3V CR123A Lithium batteries

 

Caution!

 Risk of explosion if battery is replaced by an incorrect type. Dispose of used battery according 

to the manufacturer's instructions.

 

Battery Life (for typical use)

 

3 years

 

Low Battery Threshold 

4.0 V 

Operation voltage 

4 V to 6.6 V 

Current consumption 

25 uA to 150 mA 

WIRELESS

 

 

Frequency Band (MHz)

 

868-869

 

Maximum Tx Power 

14 dBm @ 868 Mhz 

Communication Protocol

 

PowerG

 

Tamper Alert

 

Reported when a tamper event occurs and in any subsequent message, until the tamper switch is restored

 

MOUNTING

 

 

Mounting Type

 

Wall mounting 

Mounting Height

 

1.5 – 3.0 m (5 – 10 ft)

 

Horizontal Adjustment

 

-45° to +45°, in 5° steps 

Vertical Adjustment

 

0° to -10°, in 2.5° steps

 

ENVIRONMENTAL

 

 

Operating Temperatures

 

-35°C to 60°C (-31°F to 140°F)

 

Storage Temperatures

 

-35°C to 60°C (-31°F to 140°F)

 

Humidity

 

95% max. 

White Light Immunity

 

Above 25000 lux

 

PHYSICAL

 

 

Size (H x L x W)

 

157 x 147 x 124 mm (6-3/16 x 5-13/16 x 4-7/8”) 

Weight (with battery)

 

600 g (21 oz) 

Color

 

White 

PATENTS

 

U.S. Patents 7250605 

 6818881 

 5693943 (other patents pending) 

Summary of Contents for BW-ODT

Page 1: ...distinguishes between masking spray and rain Alarm LED is visible in sunlight Automatic termination of walk test after 15 minutes Microprocessor controlled temperature compensation Immunity to pets w...

Page 2: ...lay YES 5m delay YES 10m delay YES 20m delay and YES 60m delay Enable or disable the outdoor anti masking feature Optional settings Disabled default and Enabled Define whether motion alarms are always...

Page 3: ...ty com dc Certified by Norwegian accredited certification body Applica Test Certification AS in accordance with EN 50131 2 2 EN 50131 5 3 EN 50131 6 EN 50130 4 and EN 50130 5 UK This product is suitab...

Page 4: ...GE TO PROPERTY OR OTHER LOSS WHETHER DIRECT INDIRECT INCIDENTAL CONSEQUENTIAL OR OTHERWISE BASED ON A CLAIM THAT THE PRODUCT FAILED TO FUNCTION HOWEVER IF THE MANUFACTURER IS HELD LIABLE WHETHER DIREC...

Page 5: ...del terreno rilevata B Regolare gli angoli orizzontali e verticali del rilevatore si veda la Figura 3 a pagina 12 in base alla superficie da coprire La posizione dell indicatore dell angolo verticale...

Page 6: ...rilevatore Regolare l inclinazione verticale per ottenere il numero massimo di rilevamenti mentre si attraversa l intera area di 90 Verificare che il LED lampeggi ogni volta che viene rilevato un movi...

Page 7: ...l rilevatore 8 rilevatori PIR Quad indipendenti funzionanti in configurazione True Quad si veda Fig 6 Immunit agli animali Fino a 18 kg ELETTRICHE Alimentazione Due batterie al litio 3V CR123A Attenzi...

Page 8: ...rowana W Tabeli 1 przedstawiono kombinacje wysoko ci monta u w pionie oraz zasi g czujnika Podane dane dotycz wzgl dnie p askiej powierzchni Ustawienie w pionie mo na sprawdzi przeprowadzaj c test prz...

Page 9: ...atycznie prze czy si w trwaj cy 15 minut lokalny tryb diagnostyczny po za o eniu baterii lub ponownym wci ni ciu prze cznika sabota owego B Ustaw czujnik w p aszczy nie poziomej w taki spos b aby obj...

Page 10: ...u ytego sprz tu elektrycznego i elektronicznego DODATEK DANE TECHNICZNE DANE UK ADU OPTYCZNEGO Maks zasi g czarnego lustra Maks 12 m 90 Spos b wykrywania 8 niezale nych detektor w Quad PIR pracuj cych...

Page 11: ...ired after testing E Three long screw F Two short screws A Tracciare i punti di foratura B Per antistrappo C Forare D Serrare Nota I due fori consentono la regolazione della staffa sulla parete se nec...

Page 12: ...st 6 Lock A Vertical angle 4 Svitare la vite di bloccaggio 5 Regolare 6 Avvitare la vite di bloccaggio A Inclinazione verticale 4 Zwolni blokad 5 Ustawi 6 Zablokowa A Stopniowa regulacja k ta wzgl dem...

Page 13: ...Battery Insertion Figura 4 Inserimento della batteria Rysunek 4 Zak adanie baterii A LED B Enroll button C Tamper switch A LED B Pulsante di registrazione C Deviatore antisabotaggio A Dioda LED B Prz...

Page 14: ...e mail info bentelsecurity com http www bentelsecurity com D 304957 BW ODT Installation Instructions English Italian Polish Rev 2 04 22...

Reviews: