![Bentel Security BW-ODT Manual Download Page 2](http://html1.mh-extra.com/html/bentel-security/bw-odt/bw-odt_manual_2735353002.webp)
2
D-304957 BW-ODT Installation Instructions
Step 1
Step 2
Step 3
Step 4
Enter the Installer menu and select
“02:ZONES/DEVICES”
Select
"ADD NEW DEVICE"
See Note 1
Enroll the device (see Figure 5) or
enter the device ID
Select a detector number for
the new detector
or
Step 5
Step 6
Step 7
Configure Location, Zone Type and
Chime parameters
Enter PARTITIONS.
See Note 2
Assign partitions to the detector
by pressing the
,
and/or
buttons
on the panel
means scroll
and select
Notes:
[1] If the detector is already enrolled you can configure the detector parameters and assign partitions via the “Modify Devices” option – see Step 2.
[2] PARTITIONS will appear only if PARTITIONING was previously enabled in a panel that supports the Partitioning feature (for further details, see
"Partitioning" in the BW Installer Guide).
2.4. Configuring the Detector Parameters
Enter the
menu and follow the configuration instructions for the BW-ODT PIR detector as described below.
Option
Configuration Instructions
Define whether or not to activate the alarm LED indication.
Optional settings: ON (default) and OFF.
•
•
Define if the detector operates at regular or high PIR sensitivity, or that at least one detection zone must be crossed
before an alarm is triggered (One Region).
Optional settings: LOW (default), HIGH and One Region.
Note:
For EN compliance, the detector should be set to "One Region".
•
•
Define whether or not to set the activity time during Disarm mode.
Optional settings: NOT Active (default), YES – no delay, YES + 5s delay, YES + 15s delay, YES + 30s delay, YES +
1m delay, YES + 2m delay, YES + 5m delay, YES + 10m delay, YES + 20m delay and YES + 60m delay.
•
•
Enable or disable the outdoor anti-masking feature.
Optional settings: Disabled (default) and Enabled.
•
•
Define whether motion alarms are always enabled or only when dark (at night).
Optional settings: Day and Night (default) and Night only.
•
•
2.5 Local Diagnostic Test
A.
Set the detector in local diagnostic mode, as follows:
Open the detector’s bottom cover (see "Figure 4 – Battery Insertion" on the previous page, steps 1 - 3) and then press and release the tamper
switch (see "Figure 5 on page 13). The LED will flash for 60 seconds and then the detector will enter into 15 minutes' local diagnostic mode.
Note:
The detector automatically enters into 15 minutes' local diagnostic mode after battery installation or Tamper switch recovery.
B.
Adjust the detector in the horizontal plane to cover the required protected area.
C.
Walk into the detectors’ field of view. Adjust the vertical plane to receive the maximum number of detections when crossing the entire 90°
pattern. Verify that the LED blinks each time your motion is detected, as you cross one Quad PIR. Then verify that the LED lights steadily
for 2 seconds as you cross the next adjacent Quad PIR. After alarm indication, the LED blinks three times and provides the received signal
strength indication (see Table 2).
Table 2 – Received Signal Strength Indication
LED response
Reception
Green LED blinks
Strong
Orange LED blinks
Good
Red LED blinks
Poor
No blinks
No communication
02:ZONES/DEVICES
ADD NEW DEVICES
ENTR ID:XXX-XXXX
ENROLL NOW
ID No. 130-XXXX
Z0x:Motion Sens
MODIFY DEVICES
Z0x.SET CHIME
Z0x.ZONE TYPE
Z0x.LOCATION
Z0x.PARTITIONS
Z0x:P1
P2 P3
ALARM LED
PIR SENSITIVITY
DISARM ACTIVITY
OUTDOOR ANTI-M
ALARM Hours
DEVICE SETTINGS