background image

72

3

2

10

9

11

1

12

7

8

4

5

6

13

BULL 624 TURBO

Ref.

Code

Note

1

9686770

2

9688362

3

9686329

4

9686421

5

9688365

6

9686032

7

9688360

8

9686757

9

9688361

10

9688102

11

9686427

12

9688364

13

9688363

Summary of Contents for BULL 624 TURBO

Page 1: ...L8543256 06 2018 rev 1 BULL 624 TURBO UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI PORTE SERRANDE ED AFFINI IT EN DE FR ES PL ...

Page 2: ...2 2 4 34 mm A T B 3 140 330 326 330 260 210 100 91 1 ...

Page 3: ...3 1 mm T V R B Z F I G D P D V C P V C 110 mm 143 mm 5 6 7 8 ...

Page 4: ...4 A S 1 3 cm G F 9 1 mm 10 P S M C 11 OK 12 B C A K Max 35 mm X K X 3 mm 74 mm 35 mm 63 mm BULL 624 TURBO optional MLS ...

Page 5: ...5 8 7 4 1 2 3 3 x 1 5 min 2 x 1 5 RG 58 5 4 x 0 35 230V 4 6 5 2 x 0 35 3 x 0 35 H 13 14 15 16 C L ...

Page 6: ...T SELECTION MANUAL RELEASE SWITCH S I S optional J3 DL1 DL4 DL3 COSTA 8k2 N C COM SWO SWC STOP PHO PHC OPEN PED CLOSE P P COM BLINK 24Vdc 15W max AUX 2 24Vdc 0 5A max AUX 2 24Vdc 0 5A max RELAY AUX1 AUX1 BLINK BLINK 24V 24V SHIELD ANT ANT AUX1 AUX1 BLINK BLINK 24V 24V BLINK BLINK 24V 24V F2 L N BAR 24V AUX 1 MOT BATT 24Vdc MAX 1A ...

Page 7: ...7 18 19 A B C 2x12V 2 1 Ah Mod DA BT2 ...

Page 8: ...S GND B A MASTER Menu BUS ID 0 SLAVE Menu BUS ID 1 3x0 5mm 21 OPEN Open Safety Edge COM PHOTO Close Safety Edge 8K2 N O Jumper BAR BAR MOTOR J3 Open BAR N C J3 Close BAR 8K2 N C 22 bar On 20 OPEN OPEN MINV Off MINV On ...

Page 9: ...c LIGHT 24Vdc Max1A LIGHT 24Vdc Max1A 24Vdc Max1A AUX1 II CH RADIO AUX1 0001 Relè 24Vdc CH2 TX 24Vac dc 24Vac dc 24Vac dc COM NC NO RX TX COM AUX2 PHOTO 24Vdc 24Vdc 24Vdc AUX2 AUX2 0003 tst1 on SCA PHOTOTEST PHO PHOTOTEST PHC AUX2 0000 AUX2 0002 AUX2 24Vdc SERVICE LIGHT L N 230Vac LIGHT 24Vdc Max 0 5A LIGHT Relè 24Vdc COM NC NO RX TX COM AUX2 PHOTC 24Vdc AUX2 0003 tst2 on AUX2 II CH RADIO AUX2 000...

Page 10: ...c pso psc 40 50 99 99 50 sldc 20 20 20 20 20 20 TLS 60 aux1 0 aux2 1 50 TCA PAR radi Power ON Display OFF Firmware Ver 3s Diagnostic TCA htr opcl ltca phcl tst1 tst2 opcl bar aopf minv rem Schema menu di programmazione Menu programming layout Diagramm Programmiermenü Menu de programmation Menú de la carta de programación Układ menu programowania ...

Page 11: ...en Appuyez sur la touche Presionar la tecla Wcisnąć przycisk Selezionare il valore desiderato con i pulsanti e Increase decrease the value with keys and Mit den Tasten und kann man eingerichtete Werte ändern Régler la valeur désirée avec les touches et Establecer con las teclas y el valor deseado Nastawia przyciskami i obraną wartoś Premere il tasto PG Press key PG Die Taste PG drücken Appuyez sur...

Page 12: ...not to be used by persons including children with reduced physical sensory or mental capacity or who are unfamiliar with such equipment unless under the supervision of or following training by persons responsible for their safety Apply all safety devices photocells safety edges etc required to keep the area free of impact crush ing dragging and shearing hazard Bear in mind the standards and direct...

Page 13: ... Check that the gate travel during opening closing is limited by sturdy mechanical stops QUICK PROGRAMMING NOTE Quick programming conditions Receiver memory with less than 99 stored transmitters Autoset never run previously Only valid with ARC Advanced Rolling Code transmitters If you make a mistake during the quick programming procedure you can disconnect the power supply and restart the procedur...

Page 14: ...ng the 4 nuts D in the special housings located at the bottom of the geared motor Then adjust the 4 dowels by lifting the geared motor at the desired height Fix the motor by firmly tighten the 4 screws V4 M10x70 and related flat wa shers R and knurled washers Z as shown in the figure 6 4 3 POSITIONING OF THE LIMIT SWITCH BRACKETS FIG 10 Manually open the gate and leave a clearance from 1 to 3cm ac...

Page 15: ...O contact COM Common Inputs Common for all control inputs ANT SHIELD Antenna Built in radio transmitter card antenna connection ANT signal SHIELD screen 8 2 PROGRAMMING The programming of the various functions of the control unit is carried out using the LCD display on the control unit and setting the desired values in the programming menus described below The parameters menu allows you to assign ...

Page 16: ...e output is controlled by the radio channel of the built in receiver see RADIO Menu 2 Service light The contact closes for the time preset with TLS parameter The countdown starts at the inception of operation 3 Photo test Used to power the photocell transmitters in TEST mode See wiring diagram Fig 23 0 3 1 aux2 Same operation features as AUX1 output but referred to terminals AUX2 ATTENTION Max AUX...

Page 17: ...ment of the door and inverts for approx 3s both opening and closure The PHOT OPEN input re starts functioning of the photocell active on opening OFF aopf The forced opening in case of power cut off function is activated or deactivated it can be activated only with connected and operating emergency batteries On Activated function In the event of power failure before the emergency battery completely...

Page 18: ...w maneuvers for the stroke learning and the configuration of the parameters In case that the procedure is not successful the message ERR will be shown Repeat the procedure after checking the wirings and the possible pres ence of obstacles 8 4 8 PASSWORD CODE It allows to type in an access protection code to the programming of the control unit A four character alphanumeric code can be typed in by u...

Page 19: ...key of the new transmitter 4 Press within 5s the key of the new transmitter to associate to the channel chosen at point 2 The flashing light will turn off 5 The receiver memorised the new transmitter and immediately exits from programming Note function not enabled with TO GO 2 4 AK 8 7 FUSES F2 T4A General protection fuse 8 8 BACK UP BATTERIES The CP B6 1024 control panel is equipped with built in...

Page 20: ... _ _ _ _ _ _ Engineer s Signature _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Stamp Description of operation _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...

Page 21: ...enerate hazards due to wear and tear The operator is maintenance free but it is necessary to check periodically if the safety devices and the other components of the automation system work properly Wear and tear of some components could cause dangers Keep the maintenance record that must be handed to you by the installer and comply with the maintenance schedule Unplug the system from the power sou...

Page 22: ...72 3 2 10 9 11 1 12 7 8 4 5 6 13 BULL 624 TURBO Ref Code Note 1 9686770 2 9688362 3 9686329 4 9686421 5 9688365 6 9686032 7 9688360 8 9686757 9 9688361 10 9688102 11 9686427 12 9688364 13 9688363 ...

Page 23: ...AUTOMATISMI BENINCÀ SpA Via Capitello 45 36066 Sandrigo VI ITALY Tel 0444 751030 r a Fax 0444 759728 www beninca com sales beninca it ...